Atwood 900-0143-LPM Руководство пользователя - Страница 2
Просмотреть онлайн или скачать pdf Руководство пользователя для Сигнализация угарного газа Atwood 900-0143-LPM. Atwood 900-0143-LPM 5 страниц.
Welcome
Note: Many
times throughout
this User's Guide, we will
refer to
Carbon
Monoxide
as "CO".
Your new
Atwood
Carbon Monoxide
(CO) A
larm
is a sophisticated
instrument
that
has been carefully
designed
and tested to
detect
CO
build
up in a residential or recreation
vehicle
environment.
Your CO Alarm
was
built by Kidde exclusively for Atwood.
As
an owner
of a CO alarm, there
are some
basic facts you should know
about for your protection.
Many people th
ink
that
CO
alarms
operate
like smoke alarms.
Like
smoke alarms, CO alarms monitor the ai
r
in
your home and sound
a
loud alarm
to
warn you of trouble.
The
way
you
respond
to a CO alarm
is quite
different than a smoke alarm.
That's
because a house fire and a CO problem are
two
distinctly
d
ifferent
situations.
If
you
r
smoke alarm were to alarm, you would
quickly
be
able to judge
the
level
of danger
you
were in with your senses. You can
see and smell
the
smoke, feel the heat, see, and possibly hear
the
fire
burning. You can also readily see
if
your smoke alarm
is
alarming in
a
non-emergency situation.
Because
your
sense of
sight, smell,
hearing
and
touch
give you information, you can almost
instantly
judge
w
hat
action
to
take
if you hear
your
smoke
alarm.
CO
is
an
invisible,
odorless,
tasteless
and non-irritating
gas
- completely
undetectable
to
your senses. That's
wh
y
it is
important to
your safety
that
you
have
a CO
alarm.
Important Warning Statements
IMPORTANT:
This carbon monoxide alarm is designed to
detect
carbon monoxide from ANY source of combustion. It is NOT
designed to detect smoke, fire, or any other gas.
&
WARNING: Carbon monoxide alarms are not smoke ala rms.
This carbon monoxide alarm is not a substitute for
installing
and
maintaining an appropriate number of smoke alarms in your
home.
This carbon monoxide alarm will not sense smoke, fire, or
any
poisonous gas other
than carbon
monoxide even though
carbon
monoxide can be generated by fire.
For
this reason you m
u
st
install smoke alarms
to provide early warning
of
fire
and
to
protect you and your family
from fire
and
its related hazards.
&
CAUTION
:
This alarm will only
indicate
the presence of carbon
monoxide at
the
sensor. Carbon monoxide may be
present
in
other areas.
4. Installation Instructions
Mounting
This
CO alarm
can be
either
w all
mounted, ceiling mounted
or
placed
on a tabletop.
If
used
in
RV, permanently mount to wall or cei
ling
. DO NOT use
table top feature. Wall
mounting
is
recommended
for
use in
RV
applications.
For
tabletop
mounting in residential applications,
we
recommend
the
unit
be
placed
no
more than
three feet
from the floor.
For
w
all o.r
cei ling mounting,
follow
these steps:
1.
Remove back
mounting
plate
from
the
alarm
by pressing
the
locking tab
in
and sliding the
CO
alarm off
the mounting
plate.
2. Place
mounting
plate
in
desired
location and install
two
screws
provided. Tighten screws
until mounting
plate
is secure.
Do not overtighten screws
as
damage could occur.
If
mounting
into
plasterboard
I
Slide Alarm
ON
) )
.. g ...
~
or drywall,
drill
a
3/16"
hole in
the
wall and
use the two plastic
anchors provided.
3.
Install batteries
as
described
in
previous section. Note
the polarity
illustration
in the battery
compartment.
4. A lign
CO alarm to
mounting
plate and
slide into
position
ensuring
the
CO
alarm
is
fully
seated and locking tab fully secures th
e
CO
alarm
to the
mounting plate.
5.
Test
your
alarm
by
using the
Test/Reset button and check
that the
green "Power"
LED
is on.
Locking
tab
Important Warning Statements
'
&
WARNING:
This
product is intended for use in ordinary indoor
locations of family living units.
It
is not designed to measure
compliance with commercial or industrial standards. It is not
suitable for installation
in
hazardous locations as defined in the
National Electric Code.
The installation of this device should not be used as a substitute
for proper installation, use and maintenance of
fuel
burning
appliances, including appropriate
ventilation
and exhaust
systems. It does not prevent CO from occurring, nor can
it
solve
and existing CO problem.
&
WARNING: This device is designed to protect individuals
from
acute effects of carbon monoxide exposure.
It
may not fully
safeguard individuals with specific medical conditions. If in doubt,
consult a medical practitioner.
Individuals with medical problems may consider using warning
devices which provide audible and visual signals for carbon
monoxide concentrations
under
30
PPM.
This carbon monoxide alarm requires a continuous supply of
electrical power
-
it will not work without power.
This
alarm has not been investigated for carbon monoxide
detection below 70 PPM.
&
WARNING: If alarm has been subjected to abnormally cold
temperatures, the alarm may exhibit an Error condition. Allow
the alarm to warm and press the "Test/Reset" button to reset the
alarm.
TEST ALARM OPERATION AFTER VEHICLE HAS BEEN
IN
STORAGE,
BEFORE EACH TRIP, AND AT LEAST ONCE
PER
WEEK DURING USE.
Contents of This User's Guide
1.
Information About Carbon
Monoxide
2.
Product
Features
and Specifications
3.
Installation Locations
4.
Installation
Instructions
5.
900-0143-LPM Operating
Characteristics
6.
900-0140-LPM (with digital display) Operating Characteristics
7.
Alarm Characteristics
8.
Maintenance
9.
900-0143-LPM Limited Warranty
10.
900-0140-LPM
Limited
Warranty
5. 900-0143-LPM Operating Characteristics
Whenever the alarm is operating, the green Power
LED
flashes every
30
seconds to indicate the unit is monitoring for CO. If the alarm senses
dangerous levels
of CO, the red Alarm
LED
w
ill
flash and the alarm
wi
ll
emit an audible alarm pattern.
Operating and Alarm Characteristics
Function
LED Display
Alarm Sound
Unit Status
Recommendation
Normal
Green LED
None
Normal
DC
None
Operation
flashes
every
30
operation
(sensing
seconds
no CO)
and with
good batteries
Carbon
Red
LED
flashes
4
quick
beeps,
Alarm condition.
Refer
to "What
to
monoxide
with beeps.
5
seconds
Dangerous
do
When
the
Alarm
alarm
silence,
concentrations of
Sounds"
(inside front
repeating
CO detected
cover)
Low
Red LED flashes
One quick
Batteries need to be Replace
all three
AA
battery
every
60
seconds
~gefe~~~ds
replaced
batteries
Error
I
Red
LED
flashes
One
quick
Unit
is
in error
Replace
battery.
service
every
30
seconds
~~efe~~~ds
condition
If
condition
alarm
continues,
unit has
malfunctioned.
Error
Red
LED
Constant
Very
low battery
or
Replace immediately.
constantly
on
alarm
unit
malfunction
Unit
will not
respond
to
CO
Normal
Red
LED
flashes
4
quick beeps, Normal operation
CO
not detected.
TesVReset
with
beeps.
5
seconds
wh
en
TesVReset
Alarm for test
function
silence,
button
is
pressed
purposes only
repeated
once
End
of
Red LED
flashes
Two
quick
End of unit
life
Replace unit
unit
life
two
times
beeps
every
immediately. Unit
will
indicator
every
30
seconds
30
seconds
not respond to to C 0
6. Model 900-0140-LPM {with digital display)
Operating Characteristics
When
the
unit is first
powered
up, the green Operate
LED
flashes
once every
30
seconds and
the
digital
display
wi
ll
show three
"eights"
-
indicating the
alarm
is iri
the
start-up
mode. The three "eights" will
remain for
approximately
10
seconds. Then,
the
alarm wil
l
display
"O"
and begin monitoring the air for CO and will continue to do so as long
as it receives
pow
er.
This alarm
w
ill
display a "O" if
CO
concentrations between 0 and 30
PPM have been
detected
within
the
last 1 5 seconds.