Aube Technologies BDP-LX71 Руководство пользователя

Просмотреть онлайн или скачать pdf Руководство пользователя для Термостат Aube Technologies BDP-LX71. Aube Technologies BDP-LX71 2 страницы. Aube technologies inc. programmable thermostat owner's guide

Aube Technologies BDP-LX71 Руководство пользователя
Your new electronic thermostat is equipped with a microprocessor
with proportional integral adaptive (PIA) temperature control
technology for total comfort.
Clock/Day settings
Heating is On
Setpoint is displayed
Return/Exit
when arrow appears
Power (On/Off)
Program settings
Manual mode
Installation & Wiring
1.1
Guidelines
Turn off power to the heating system at the main power panel to
avoid electrical shock. The installation must be performed by an
electrician.
High voltage thermostats must be installed onto an electrical
box.
For a new installation, choose a location about 1.5 metres above
the floor.
The thermostat must be installed facing the heating system.
The thermostat must be installed on an inside wall.
Avoid locations where there are air drafts (top of staircase, air
outlet), dead air spots (behind a door), direct sunlight or
concealed chimneys or stove pipes.
1.2
Installation Procedure
Remove the screw holding the control module to the power
base.
NOTE:
Please note that the screw cannot be completely removed.
Lift the control module to remove it from the power base.
On the power base, remove the screw holding the wire cover
and wire the thermostat.
NOTE:
The terminals are designed for wires of cross-section mea-
2
suring 0.33 to 2.5 mm
.
Once all wiring is complete, secure wire cover.
Secure the power base onto the electrical box using the
mounting holes.
Mount the control module onto the power base and secure using
the screw.
Return power to the heating system.
NOTE:
Keep the thermostat's air vents clean and free from obstruc-
tions.
TH136
TH136 Programmable
Thermostat
Owner's Guide
Auto mode
Current program
Adjustment buttons
Remote Input Wiring
The TH136 is equipped with a remote input which allows connection of a
telephone controller (optional CT240) or a home automation system.
When a signal is received through this input, the TH136 will automatically
switch from normal operating mode to Frost Protection
versa.
NOTE:
For details on operating the telephone controller, see Operating
Modes.
2.1
Connection to the CT240
Connect CT240 terminals A and C to
TH136 terminals X and C respectively.
You must respect the polarity.
2.2
Connection to a home
automation system
Connect the TH136 to the home
automation system as displayed in the
wiring diagram.

Installing the Batteries

When you first install the batteries, the unit runs a
1.
sequence of tests which lasts approximately 5 seconds.
After the tests, the screen should display the current
temperature.
NOTE:
We recommend replacing the batteries at least
once a year.
The TH136 will display an icon
batteries must be replaced. This icon will be displayed
for 60 days; after this delay, the TH136 will shut down
the heating unit. Once batteries have been replaced,
you will have to reprogram the clock & day settings; all
other programming is stored in a protected memory.
On/Off Button
The thermostat is equipped with an On/Off button
making it possible to put the thermostat in sleep mode
when its use is not required (e.g. summer). This will not
affect the clock or programming.
Clock and Day Settings
Press
; the hour segment flashes.
Press
to set the hour.
Press
; the minutes segment flashes.
Press
to set the minutes.
Press
; the day flashes.
Press
to set the day.
Press
to exit.

Operating Modes

5.1
Automatic
Executes the schedule. Press Auto to activate the
Auto mode.
5.2
Manual
Maintains a constant temperature. Press
activate the Manual mode and set the temperature
using
.
5.3
Frost Protection
Maintains the Frost Protection setpoint during a
prolonged absence. The Frost Protection setpoint is
pre-programmed to 10°C. To modify, see Advanced
Programming. There are 2 ways to activate the
Frost Protection mode:
From the thermostat:
Press
for 1 second to activate the Manual
mode. Hold
displayed. To deactivate the Frost Protection
mode, activate the Auto or Manual mode.
From a telephone (remote location) when the TH136
is connected to a CT240 telephone controller.
NOTE:
For details on how to activate the Frost Protection mode using a
telephone, refer to the CT240 Instruction Manual.
WARNING:
When the Frost Protection mode is activated remotely, it
must be deactivated remotely.
indicating that the
for 3 seconds. The
icon is
400-136-001-C
2008-02-01
2.
mode, or vice
3.
4.
5.
to
Automatic
Manual
Frost Protection
1/2