Output port

CT7301 demo board has 3 kinds of output, SPDIF(toslink x1, coaxtial x1), I2S, and
DSD.
Input signal
PCM data
Non-PCM data
Native DSD data
(enable D2P)
Native DSD data
(disable D2P)
DoP data
(enable D2P)
DoP data
(disable D2P)
H/W configuration setting
CT7301 H/W configuration is controlled by PORx pins. You could modify the
settings by Jumper J21.
Connect the left two pins = 0.
Connect the right two pins = 1
PORx setting table:
Pin Name
POWER_ON_LATCH[1] = SEL_DSD_I2SZ_IN
POR[1]
POWER_ON_LATCH[3:2] = SEL_XTAL[1:0]
POR[3:2]
Version 0.9
SPDIF port
PCM
Non-PCM
Non-PCM
PCM
DoP
PCM
DoP
Description
Select DSD or I2S-channel2 pins definition (pin 13,14,15)
0 = I2S channel 2
1 = DSD
Select Crystal frequency
00 = 12MHz
Copyright © 2014 comtrue Inc. All rights reserved.
I2S port
DSD port
PCM
Mute
Mute
PCM
DSD
DoP
DSD
PCM
DSD
DoP
DSD
Function Table