Auber Instruments HD330-W Дополнительное руководство - Страница 3

Просмотреть онлайн или скачать pdf Дополнительное руководство для Контроллер Auber Instruments HD330-W. Auber Instruments HD330-W 5 страниц. Wireless dual output programmable humidity controller

AUBER INSTRUMENTS
4
Figure 7. Device List page.
(1) Add a new device.
(2) App menu button.
(3) Refresh device list.
(4) Device quick-view. Short tap it to view the device information page;
long tap it to bring up a quick action menu.
(5) Device name.
(6) Current program step number.
(7) Current probe reading.
(8) Device sticky to the top of the list.
(9) Quick action menu.
(10) App menu.
4.2 Device information page
The device information page shows the current device status, past data
collection, and allows users to change program running status. This page can
be divided into four sections: A) quick access bar, B) data plot, C) device
working status, and D) program details.
A. Quick access bar
(1) Return back to the Device List page.
(2) Change program status to Run/Pause/Stop. This action is password
protected.
(3) Mute alarm buzzer.
(4) Configuration button. Go to Device Settings and App Preferences.
These options are password protected.
B. Data plot
(5) Plot legend.
(6) Plot time scale selection. Plot's time scale can be changed between 2
hours, 6 hours, 24 hours, 7 days, or 30 days (see Figure 9).
(7) Humidity data plot. Tap on the plot to check information on specific data
points (see Figure 10).
C. Working status
(8) Current humidity reading.
(9) Set value at current step.
(10) Current program step.
(11) Progress bar.
D. Program status
(12) Program status. Show whether the program is running/paused/stopped
(13) Step time. It shows how much time has passed in the current step and
how much is the total time of the current step.
2021.06
1
2
3
5
8
6
7
(14) Total time shows the total passed time and total time of the entire
program.
(15) Device run time shows how much time has passed since the device
was powered on.
Figure 7. Device information page.
Figure 9. Change the time scale of the data plot.
7
Figure 10. Check a data point on the plot.
4.3 Device settings and app preferences
To check or change the device settings or app preferences, click on the
Configuration button on the Quick Access Bar of the Device Info page.
WWW.AUBERINS.COM
P3/5