3onedata TNS5000D Series Руководство по быстрой установке - Страница 2

Просмотреть онлайн или скачать pdf Руководство по быстрой установке для Переключатель 3onedata TNS5000D Series. 3onedata TNS5000D Series 3 страницы. Unmanaged wall-mounted industrial ethernet switch

Nail screws on the wall and keep 7mm interspace
reserved.
Hang the device on 4 screws and slide downward,
then tighten the screw. Mounting ends.
【Wall-mounted Device Disassembling】
Power off the device.
Unscrew the screw on the wall about 7mm.
Lift the device upward slightly; take out the device,
disassembling ends.
Notice before power on:
Power ON operation: First insert the power supply
terminal block into the device power supply interface,
then plug the power supply plug contact and power on.
Power OFF operation: First, remove the power plug,
then remove the wiring section of terminal block. Please
pay attention to the above operation sequence.
【Power Supply Connection】
This series device provides 1 DC power input,
and the interface adopts M12 A-Coded 4-Pin
connector (male), in which the power supply
occupies two pins V- and V+, which can be
connected with M12 A-Coded 4-Pin slot (female).
Model I power input range: 110VDC(66~154VDC);
Model II power input range: 24VDC (9~36VDC).
The pin definitions of M12 (male) are shown as follows:
Pin
V+
V-
Definition
Positive
Negativ
Description
power
e power
input
input
【Service Port Connection】
command management of the device. The interface adopts
M12 D-Coded 4-Pin slot (male).
The pin definitions of M12 are shown as follows:
Pin
Definition
Description
Note: Service port is only for debugging by our technicians.
【Communication Interface Connection】
【Checking LED Indicator】
The series of devices provide LED indicators to monitor its
operating
RELAY1
RELAY2
troubleshooting process. The function of each LED is
described in the table below:
LED
Reserved
Reserved
PWR (X1)
This
series of
device
provides
debugging port of M12 D-Coded 4-Pin(Female)
connector, which can be connected with PC for CLI
TX
RX
NC
RS-232 send
RS-232
signal
receive
Reserved Ground
signal
This device provides 8 10/100Base-T(X) interfaces,
the interface type is M12 D-Coded 4-Pin slot
(female). The definitions of M12 pin are as follows:
Pin No.
Definition
Description
1
TD+
Positive send data of
100M Ethernet
2
RD+
Positive receive data of
100M Ethernet
3
TD-
Negative send data of
100M Ethernet
4
RD-
Negative receive data
of 100M Ethernet
status,
which
has
simplified
Indicate
Description
PWR is connected and running
ON
normally
OFF
PWR is disconnected and
a
program
ON
RUN
OFF
Blinking
GND
ON
Link
Blinking
(X11-X18)
OFF
【Specification】
Panel
Power supply interface
Relay interface
Reserved
100M Ethernet port
Service debugging port
Indicator
the
overall
Switch Property
Backplane bandwidth
Packet buffer size
MAC Address Table
Power Supply
running abnormally
The device is powering on or the
device is abnormal.
The device is powered off or the
device is abnormal.
Blinking 1 time per second,
system is running normally
Ethernet port has established a
valid network connection
Ethernet port
is in an active
network status
Ethernet
port
has
not
established
valid
network
connection
M12(Male), 4-Pin A-Coded, the
power supply occupies two pins
V- and V+
M12 (Male), 4-Pin A-Coded,
relay occupies two pins,
RELAY1 and RELAY2
10/100Base-T(X),
M12(Female), 4-Pin D-Coded,
Automatic Flow Control,
Full/half Duplex Mode,
MDI/MDI-X Autotunning
M12 (Female) ,4-PinD-Coded
Power
indicator,
running
indicator,
alarm
indicator
(reserved), interface indicator
7.6G
1Mbit
8K