5.12 Analog input
The function is used for current signal, 4-20mA, for future definition.
AIN Off/On/On+Al
AIN Al.lim.1 HH
AIN Al.lim.2 H
AIN Type
AIN Range
AIN Zero calibr.
AIN Span calibr.
5.13 FeedGuard func.
FG Result
FG Type
FG Pist.length
FG Safe dist.
FG Timeout
FG Pist. Delay
FG CMD speed
FG Chk. max pos.
5.14 Rotor Move Ctrl.
The function is only valid and shown in a BRM-DM1.
RMC Function
RMC Prod. pos.
RMC Start offset
RMC Set Prod.pos
RMC Power limit
RMC Time limit
RMC Min prod.pos
RMC Max prod.pos
5.15 Rotor Move Adj.
The function is only valid and shown in a BRM-DM1.
RMA Touchp.func.
RMA Touchp.level
RMA Touchp. Time
RMA Touchp. pos.
RMA Wear setting
RMA Wear offset
RMA Status
BRM-DM12 UM EN.docx
BRM-DM1/2
Off=disconnected, On=connected, On+Alarm=connected to the sum alarm function
Alarm limit 1, high-high.
Alarm limit 2, high.
Measure function. Set 0.
Range.
Zero calibration, se calibration manual for actual measure system.
Span calibration, se calibration manual for actual measure system.
Rotor travel distance at the latest FeedGuard release.
Type, 0 = disconnect, 1 = connected and PLC controls rotor, 2 = connected and
BRM controls the rotor, 3 – not used.
Ventil-length (mm).
Safe distance (mm).
Time, the amount of time before the evaluation is done (s).
Delay time for the piston (s).
Rotor travel speed(mm/s).
Maximum control limit. No check is done at a POM-value above this limit.
Function, "Off" = disconnected. "Static op." = static mode, the production position
is not changed in operation. "Dynamic op." = dynamic mode, the production
position is decreased automatic in operation when the gap is lowered (and enough
motor power under a minimum of time).
Actual production position (mm).
Offset between the start position and the production position (mm).
Set a permanent production position. Set to a desired production position in static
mode or to 0.00 in dynamic mode (mm).
Minimum power to be able to decrease the production position in dynamic mode
(MW).
Minimum time to be able to decrease the production position in dynamic mode
(min)
Minimum allowed production position (mm).
Maximal allowed production position (mm).
Function. "Static" = static calibration med standstill refiner.
"Manual " = manual calibration med rotating discs and the operator maneuvers the
plates completely. "Automatic" = automatic calibration with rotating discs and the
operator maneuvers the plates to the touch point and BRM then maneuvers the plates
apart. "PLC ctrl." = The function is controlled by the DCS/PLC via the industrial
bus.
Minimum touch value (TVD) to determine the contact position (%).
Minimum time as the TVD value has be over the limit to detect the contact position
(s).
Contact position (mm)
Setting for measurement of the plate wear. 0 = disconnected, 1 = automatic
measurement, 2 = reset measurement relative the actual rotor position. Note - after a
reset (2), the previous value is restored.
Rotor position value for the measurement of the plate wear (mm).
Status value for RMC/RMA-the function (described in a separate document).
Feb. 18, 2020
User manual
Page 8 of 10