3
Fix the outer wrapper to the frame.
Place the wrapper at the hole and fix with the appropriate
screws and seal gasket . Purchase from T
supplied with the unit.
Seal gasket
Secure it with screws
4
Inst all the drain p an at the right corner of the
outer wrapper .
5
Slide the chassis back into the outer wrapper
PROBLEM
1. Blown fuse
2. Circuit breaker tripped
Unit does not st art
3. Unit cord unplugged
4. Supply volt age too low .
1. Air filter dirty
2. Improper thermost at setting.
Unit does not cool
3. Unit on dry mode.
properly
4. Unit on sleep mode.
5. Check if the air conditioner is
1. Check whether fan hitting
Fan motor does
not run
2. Check fan motor bearing.
1. Low out side temperature.
2. Air filter dirty.
Ice or frost forms
3. Check system for leak.
on indoor coil
4. Check thermostat.
1. Outer wrapper not tilted properly
Water dripping
into the room
2. Drain hole clogged.
E5
Coil thermistor problem
Control
E4
Room thermistor problem
Panel
E3
Unrecoverable loss of E2RAM dat
Error
Loss or corruption of stored dat a
E2
Code
E1
Code validation check fail
(Fo r ele ctronic
model o nly)
Filter check warning
FL
Lock the chassis to the outer wrapper reusing
6
the screw .
otaline if not
Frame
10 mm
tilt (max.)
*For Chassis 1
Bracket (n ot include d)
40~45 mm
Screws
Drain pan
Attach the front grille to the outer wrapper
7
.

TR OUBLESHOO

TING GUIDE
POSSIBLE CAUSE
exposed to sunlight.
cowling or foreign material.
on the outside.
a
Connect the
ground wire
C lockwis e
C lockwis e
*For Chassis 2 & 3
*For PMX
Clockwise
SOLUTION
1. Replace only once.
2. Reset only once .
3. Replug into wall recept acle.
4. Consult electrician.
1. Clean the air filter .
2. Reset to desired temperature setting.
3. Press cool button.
4. Press sleep button.
5. Provide an awning.
1. Adjust fan position or remove the
foreign material.
2. Replace fan motor .
1.Operate the fan without cooling until
the frost disappears.
2. Clean the air filter .
3. Rep air and recharge.
4.Replace thermost at if defective.
1. Tilt the outer wrapper by maximum of
10mm.
2. Clean drain hole.
Check coil thermistor
Check room thermistor
Shut down the unit and restart.
Using remote control, go to Cool mode
and shut down the system, & then restart.
Shut down the unit and rest art
Press the 'mode" and " " (down)
buttons simultaneously for 3-5 sec.
.