Anyload DD-KC1 Руководство по эксплуатации - Страница 9
Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Аксессуары Anyload DD-KC1. Anyload DD-KC1 11 страниц. Digital weight indicator
Также для Anyload DD-KC1: Руководство по эксплуатации (13 страниц)
parameter;
e) Press the
f) After all the parameters have been set, switch the menu to "-End-", and press the
button to finish the setting and save the parameters, then return to the
weighing or counting mode.
Menu
Meaning
Menu
1.codE
Check
internal code
2.ASt
Zero
tracking
range
3.out
Printout
method
4.LEd
Backlight
control method
5.OFF
Automatic
shutdown
control
6.-LL-
Set Lower limit
alarm
7.-HH-
Set upper limit
alarm
-End-
Finish
measuring
and save the
parameters
6.Meaning of Cue Code
Display Code
Meaning of Code
no
1. The calibration weight value is
not loaded according to the display
when calibrating.
2. The quantity of objects is not
loaded according to the quantity of
Page 9 of 11
button to confirm the parameter, and return to the menu;
Table 3
of
Selectable
Parameter
the
null
0.5/1/2/3d
kEy/Auto/Co
nti
OFF/Auto/on
no/3/510/15/
30/60 min
Xxxx (lower
limit value)
xxxx(upper
limit value)
null
Meaning of Parameter
Check the internal code for debugging by
manufacturer.
Set automatic zero tracking range.
kEy:printout while press the key,Auto:
printout automatically , Conti : printout
continuously
OFF : backlight is turned off , Auto :
backlight is automatic,On:backlight is
turned on.
No: no automatic shutdown; 3~60min: if
no action of weighing objects or pressing
buttons, the instrument will automatically
turn off.
If the lower limit value is set to"0", the
lower limit alarm function is canceled.
If the upper limit value is set to"0", the
upper limit alarm function is canceled.
Table 4
Solution
1. Load the weight value
according to the show value.
2.
according to the show value.
Anyload-manual-indicator-DD-KC1-en-101
Load
the
quantity