anytronics Anyscene 512 Руководство по установке и эксплуатации - Страница 9

Просмотреть онлайн или скачать pdf Руководство по установке и эксплуатации для Контроллер anytronics Anyscene 512. anytronics Anyscene 512 13 страниц. Scene recall unit

6.3. Fade Rate

The full-scale fade period from one scene to another can be adjusted using the two DIL
switches marked Fade x 2 and Fade x 4. The adjustment is as follows,

6.4. Clearing All Memories

To clear all saved scenes within the Anylight 512 the following procedure should be
followed,
a) With the power removed
b) Hold both the Up and Down level buttons
c) Power the unit whilst continuing to hold both buttons
d) If this operation has been successful, the Data LED on the Anyscene 512 will light
after approximately 4 seconds. It will cycle briefly on then off for 4 seconds until
the Up and Down level buttons are released.
Units 5 & 6 Hillside Industrial Estate
London Road, Horndean,
Hampshire, PO8 0BL
Tel +44 (0)23 9259 9410
Fax +44(0)23 9259 8723
Fade x 2
Fade x 4
OFF
OFF
OFF
ON
ON
OFF
ON
ON
Page 9 of 13
Fade Time (Seconds)
2.5
5
10
20
Anyscene 512 Operating
AT1039 Issue 1
Instructions