Anywave ATSC 60W Краткое руководство по эксплуатации - Страница 13
Просмотреть онлайн или скачать pdf Краткое руководство по эксплуатации для Передатчик Anywave ATSC 60W. Anywave ATSC 60W 17 страниц.
10. (Optional Step) Navigate to the Exciter "DPD" submenu in the Advanced User
menu (simultaneously press Left and Right buttons, then simultaneously press
UP and Down buttons). Be sure the value of Feedback Sample Signal Input
(FSSI) for both A (after) and B (before) reads somewhere between 45% and 75%
- which roughly corresponds to a value of -15 to -5 dBm as measured on a power
meter (note: the FSSI indicator toggles between A and B and will "flash" when
the signal level is out of range, too high or too low). Add or remove the
appropriate attenuator padding to achieve feedback signal levels in the desired
range. Note the AFTER filter feedback sample is used to compute the SNR and
Shoulder Metrics displayed.
11. (Optional Step) Navigate to the Exciter "SYSTEM" submenu and select
UPDATE under ADPC to run corrections. The exciter will then proceed through
4 stages of correction, computing Linear and Non-Linear corrections, and
automatically saving the coefficients into non-volatile memory upon
completion. The correction process typically takes from 8-10 minutes to
complete while real-time performance metrics of SNR and Shoulder
performance are displayed on the LCD.
12. Check RF Performance metrics (SNR, LIMD, UIMD) on the front panel screen
of the exciter, as well as on the PA's touchscreen.
Your TX should now be up and running properly into your load or on-air
antenna. Continue to monitor system parameters as you allow the transmitter to
operate and stabilize at full output power for another 30 minutes.
ACT-PAU01-QSG-DOC-V1.1, 06/26/2018
ATSC 60W Quick Start Guide
Page 13 of 17