Anywire ASLINKER BL2LN87SB-02D CC20 Series Руководство по эксплуатации системы - Страница 18

Просмотреть онлайн или скачать pdf Руководство по эксплуатации системы для Адаптер Anywire ASLINKER BL2LN87SB-02D CC20 Series. Anywire ASLINKER BL2LN87SB-02D CC20 Series 20 страниц.

[Equipment Parameters and Their Settings]
Equipment
Setting item
parameter
Disconnection
monitoring function
1
setting
Disconnection
2
detection enabled
CH setting
Power supply line
disconnection
3
information
*
For read only
Signal line
disconnection
4
information
*
For read only
Alarm information
5
output destination
setting
Signal line
6
disconnection
clear command
7 to 11
Spare
Short-circuit
noti cation cancel
12
setting
Alarm information
noti cation
13
pattern setting
Short-circuit
14
noti cation
cancel command
Spare
15 to 19
Description
Used to specify whether the
disconnection detecting function is
enabled or disabled.
Factory setting: 0003
Used to specify a number of input
channels subject to this function when the
disconnection detecting function is used.
Factory setting: 0000
Used to check power supply line
information when disconnection is
detected.
Used to check signal line information
when disconnection is detected.
Used to specify alarm information
output destination in the input area of
the resend unit.
Factory setting: 0000
Used to clear a signal line
disconnection error.
Factory setting: 0000
Used to specify how to clear
short-circuit status after short-circuit is
detected.
Factory setting: 0000
Used to specify an alarm information
noti cation pattern.
Factory setting: 0000
Used to clear a short-circuit error when
short-circuit noti cation cancel setting
is "manual restoration."
Factory setting: 0000
-BL2LN87SB02D*CC20 18/20-
Variable
Disconnection detecting function OFF
0000
Monitoring enabled for power supply line only
0001
Monitoring enabled for signal line only
0002
Monitoring enabled for both power supply and signal lines
0003
Both IN0 and IN1
0000
0001
0002
0000
0001
Disconnection of IN0 only
0002
Disconnection of IN1 only
0003
Disconnection of both IN0 and IN1
0000
0001
Disconnection of IN0 only
0002
Disconnection of IN1 only
0003
Disconnection of both IN0 and IN1
0000
Subsequent to input signal
0001
Latter half of input information area
0000
Clear command OFF
0001
Clear command ON
0000
Automatic restoration
0001
Manual restoration
0000
Alarm noti cation OFF
0001
Noti cation by differentiating disconnected
CH (When ALM bit is normal: OFF)
Noti cation by differentiating disconnected
0002
CH (When ALM bit is normal: ON)
Noti cation by differentiating disconnected
0003
CH and short-circuit/power supply drop
(When ALM bit is normal: OFF)
Noti cation by differentiating disconnected
CH and short-circuit/power supply drop
0004
(When ALM bit is normal: ON)
Noti cation by differentiating sensor cable
0005
error/voltage drop
(When ALM bit is normal: OFF)
Noti cation by differentiating sensor cable
0006
error/voltage drop
(When ALM bit is normal: ON)
0000
Cancel command OFF
0001
Cancel command ON
Description
IN0 only
IN1 only
Normal
Normal