【DIP Switch Settings】
Provide 4 pins DIP switch for function settings,
where "ON" is enable valid terminal. The device
needs to be powered on again to change the status of DIP
switch.
DIP switches definition as follows:
DIP
Definition
Operation
1
Reserved
-
2
Restore factory
Set the DIP switch to ON,
defaults
power on the device again, it
will restore to factory settings,
then turn off the DIP switch.
3
Reserved
-
4
Reserved
-
【Serial Port Connection】
3IN1 Interface
The model I of this series provides 3IN1 serial
port, which supports RS232, RS485 and RS422
at the same time. The interface type is RJ45 and
its pin definitions are as follows:
PIN
1
2
3
4
RS-232 DSR RTS GND TXD RXD DCD CTS DTR
RS-485 —
GND —
RS-422 —
R-
GND R+
RS-485/ 422 interface
The model II of this series provides 5-Pin
5.08mm pitch terminal blocks. The serial
port is isolated and its pin definitions are
as follows:
PIN
1
2
3
RS-485
D+
D-
GND
RS-422
T+
T-
GND
【Checking LED Indicator】
The device provides LED indicators to monitor the device
working status with a comprehensive simplified
troubleshooting; the function of each LED is described in the
table as below:
LED
PWR
RUN
LINK (1-2)
5.
6
7
8
TX(1-8)
D-
D+
T-
T+
RX(1-8)
【Logging in to WEB Interface】
This device supports WEB management and configuration.
Computer can access the device via Ethernet interface. The
4
5.
way of logging in to device's configuration interface via IE
browser is shown as below:
R+
R-
Step 1
Indicate
Description
PWR is connected and running
ON
normally
PWR is disconnected and
OFF
running abnormally
System runs normally
Blinking
The system is not running or
OFF
running abnormally
System is running abnormally
ON
Copper port has established an
ON
active network connection.
Copper port is in a network
Blinking
activity state.
Copper port has not established
OFF
an active network connection.
No data or abnormal data is
OFF
being transmitted through serial
port.
Blinking
Serial port is transmitting data.
Serial port is not receiving data
OFF
or receiving data abnormally
Blinking
Serial port is receiving data.
Configure the IP addresses of computer and the
device to the same network segment(The network
segment of Network Port 1 is 1, and the network
segment of network port 2 is 8), and the network
between them can be mutually accessed.
Step 2
Enter device's IP address in the address bar of the
computer browser.
Network Port 1:
Network Port 2:
Step 3
Enter device's username and password in the login
window as shown below.
Step 4
Click "OK" button to login to the WEB interface of
the device.
Notes:
The default IP address of the device network port 1 is
"192.168.1.254", port 2 is "192.168.8.254".
The default user name and password of the device are
"admin".
If the username or password is lost, user can restore it to
factory settings via device DIP switch or management
software; all modified configurations will be cleared
after restoring to factory settings, so please backup
configuration file in advance.