Danfoss AK-CC55 Руководство по установке - Страница 10

Просмотреть онлайн или скачать pdf Руководство по установке для Контроллер Danfoss AK-CC55. Danfoss AK-CC55 16 страниц. Single coil
Также для Danfoss AK-CC55: Руководство по установке (18 страниц)

Danfoss AK-CC55 Руководство по установке

Menu survey

Menu set via display
Parameters
Function
Normal operation
Temperature (setpoint)
Thermostat
Differential
Max. limitation of setpoint setting
Min. limitation of setpoint setting
Temperature unit (°C/°F)
Correction of the signal from S4
Correction of the signal from S3
SEr: Manual control (-1), OFF: Stop control (0), ON:
Sta<rt control (1)
Displacement of reference during night operation
Define thermostat function
1=ON/OFF, 2=Modulating
Definition and weighting, if applicable, of thermostat
sensors - S4% (100%=S4, 0%=S3)
Time between melt periods
Duration of melt periods
Temperature setting for thermostat band 2.
As differential use r01
Definition and weighting, if applicable, of thermostat
sensors when night cover is on (100%=S4, 0%=S3)
Heat function
Neutral zone between refrigeration and heat function
Time delay when switching from refrigeration to heat
function
Food type: use settings listed in table
Min. limit for S4 temperature
Alarms
Delay for temperature alarm
Delay for door alarm
Delay for temperature alarm after defrost
High alarm limit for thermostat 1
Low alarm limit for thermostat 1
High alarm limit for thermostat 2
Low alarm limit for thermostat 2
Alarm time delay or signal on the DI1 input
Alarm time delay or signal on the DI2 input
Signal for alarm thermostat. S4% (100%=S4, 0%=S3)
Compressor
Min. ON-time
Min. OFF-time
Time delay for cut-in of comp. 2
Switch mode for 2 compressor operation.
= 1 sequentially. = Cyclic 2
Defrost
R-W
If the operation is limited by a setting of one or more passwords, reading and setting the parameter will be limited to:
R: This setting can be seen with password no. _ or higher.
W: This setting can be performed with password no. _ or higher (3 is the highest level).
*) In order to change this parameter the regulation must be stopped via the parameter r12 Main switch = OFF.
**) In order to change this parameter the parameter r12 Main switch must be set in position "SEr" allowing manual control of outputs.
10 | AN300028324304en-000401
Wiring diagram pages 2-4
R-W
Code
1
2
3
4
0-0
r00
1
1
1
1
1-2
r01
1
1
1
1
0-2
r02
1
1
1
1
0-2
r03
1
1
1
1
1-2
r05
1
1
1
1
1-2
r09
1
1
1
1
1-2
r10
1
1
1
1
0-2
r12
1
1
1
1
1-2
r13
1
1
1
1
1-2
r14
1
1
1
1
1-2
r15
1
1
1
1
1-2
r16
1
1
1
1
1-2
r17
1
1
1
1
0-2
r21
1
1
1
1
1-2
r61
1
1
1
1
1-2
r62
1
1-2
r63
1
1-2*
r89
1
1
1
1
1-2
r98
1
1
1
1
1-2
A03
1
1
1
1
1-2
A04
1
1
1
1
1-2
A12
1
1
1
1
1-2
A13
1
1
1
1
1-2
A14
1
1
1
1
1-2
A20
1
1
1
1
1-2
A21
1
1
1
1
1-2
A27
1
1
1
1
1-2
A28
1
1
1
1
1-2
A36
1
1
1
1
1-2
c01
1
1
1
1
1-2
c02
1
1
1
1
1-2
c05
1
1-2
c08
1
Min. value Max. value
5
6
7
8
9
1
1
1
1
1 "r03"
1
1
1
1
1 0.1 K
1
1
1
1
1 "r03"
1
1
1
1
1 -50°C
1
1
1
1
1 0/°C
1
1
1
1
1 -10 K
1
1
1
1
1 -10 K
1
1
1
1
1 -1
1
1
1
1
1 -50 K
1
1
1
1
1 1
1
1
1
1
1 0 %
1
1
1
1
1 0 hrs
1
1
1
1
1 0 min.
1
1
1
1
1 -50°C
1
1
1
1
1 0 %
1 0 K
1 0 min.
1
1
1
1
1 0
1
1
1
1
1 -50°C
1
1
1
1
1 0 min.
1
1
1
1
1 0 min.
1
1
1
1
1 0 min.
1
1
1
1
1 -50°C
1
1
1
1
1 -50°C
1
1
1
1
1 -50°C
1
1
1
1
1 -50°C
0 min.
1
1
1
1
1 0 min.
1
1
1
1
1 0 %
1
1 0 min.
1
1 0 min.
1 0 sec
1 1
SW = 2.0x
Factory
Actual
setting
setting
"r02"
2
20 K
2
50°C
50
"r02"
-50
1/F
0/°C
10 K
0
10 K
0
1
0
50 K
0
2
1
100 %
100
10 hrs
1
30 min.
5
50°C
2
100 %
100
50 K
5
240 min.
240
5
0
50°C
-50
240 min.
30
240 min.
60
240 min.
90
50°C
8
50°C
-30
50°C
8
50°C
-30
240 min.
30
240 min.
30
100 %
100
30 min.
0
30 min.
0
999 sec
5
2
2
© Danfoss | DCS (vt) | 2019.10