Duke ACTW-1 Руководство по эксплуатации - Страница 8
Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Подогреватель продуктов Duke ACTW-1. Duke ACTW-1 12 страниц. Countertop warmer
https://appliancetechmanuals.com
Service Manual for Countertop Warmer
Element Replacement
Location of Element Pan
General
The element pan is located on the under side of
the pan (see Figure 5). The element is mounted
on the element pan.
1. Unplug unit from power source.
2. Remove the bottom cover.
3. Tag and disconnect the element wiring.
4. Remove the element pan.
5. Remove the element from the pan
(see Figure 6).
Element Installation
6. Replace new element in the pan.
CAUTION: Use care when handling
the new element, which
will break very easily.
8
Figure 5
Figure 6
7. Use an ohm meter to test the new element
for continuity.
8. Replace the element pan.
9. Using the tags, reconnect the element
wires.
10. Install the bottom cover.
11. Plug the unit into a GFI outlet.
Hi-Limit Thermostatic Switch
Replacement
Figure 7
Location of Hi-Limit Thermostatic Switch
General
The Hi-Limit thermostatic switch is located on the
bottom of the pan next to the element wires (see
Figure 7).
1. Disconnect unit from power source.
2. Remove the bottom cover.
3. Tag the wires to the Hi-Limit thermostatic
switch and disconnect them.
4. Remove the Hi-Limit thermostatic switch.
5. Replace the Hi-Limit thermostatic switch.
6. Using the tags, reconnect the Hi-Limit
thermostatic switch wiring.
7. Install the bottom cover.
8. Connect the unit to its power source.