DUKER 451 Руководство по эксплуатации - Страница 15

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Блок управления DUKER 451. DUKER 451 19 страниц. Resilient seated butterfly valves

Move the disc (3) to the open position and remove the countersunk screws (23).
Remove the retaining ring (4) after removing the countersunk screws (23).
Replace profile sealing (9), remove soiling in sealing area. Check the exact location of the profile
sealing (9) in the retaining groove.
Fill threaded holes for the countersunk screws (23) with glass adhesive.
Tighten the countersunk screw (23) on the retaining ring (4) to the specified torque.
9 (new)
Move the valve disc (3) to the "CLOSED" position.
Pressure test; depending on the pressure level.
Issue 04
23
33
4
3
Düker GmbH – www.dueker.de
3
2
9 (used)
page 15