Chemical Set Up
1. Select proper mix tip (provided) for soap and set
aside for future installation.
Consult Hydrominder instructions and chemical
product label for further dilution information.
2. Attach chemical suction tube to inlet port on
eductor and place other end with foot valve
strainer and weight into bulk soap container.
3. Attach discharge tube assembly with orifice side
up to eductor outlet. (Fig. 7)
4. Run beaded chain on float assembly through
eyelet of yoke. (Approx. 6" of chain) (Fig. 7-A)
Purging Air out of the Chemical Suction Tube
5. Turn the water on slowly until the chemical
suction tube fills with soap.
6. Remove the chemical suction tube.
7. Now, install the mixing tip set aside earlier.
8. Reinstall the chemical suction tube.
9. Fill tank to 2/3 capacity. The level is set by
changing the length of the beaded chain on the
float assembly. (Fig. 7)
Chemical Adjustment Notes
Installation & Operating Instructions | 5
Chemical
Suction
Tube
Discharge Tube
Assembly
Figure 7
Purging Air out of the Chemical Suction Tube
After the air is purged, remove any water
left in the tank or add a higher concentrate of
chemical to adjust for the water level.
This will ensure you get a more consistent foam.