Duluth Forge FNVL18-1 Руководство - Страница 3
Просмотреть онлайн или скачать pdf Руководство для Газовый обогреватель Duluth Forge FNVL18-1. Duluth Forge FNVL18-1 20 страниц. Vented natural gas logs
Note: This vented appliance must be installed
only in a solid-fuel burning fireplace with a
working flue and constructed of noncombus-
tible material.
The charts indicate technical information
regarding the installation of your gas log set.
Model
Gas Type
BTU Input*
Minimum Vent Opening
Burner Orifice (Propane/LP)**
* Btu/Hr Rating is the same when unit is converted to Propane/LP gas.
** Number is printed on orifice. Located in NVDWA2 kit when converting to LP gas.
Natural Gas
Propane/LP Gas*
* For use if unit is converted to Propane/LP gas.
* Add 4" when using on/off valve safety pilot kit
IMPORTANT: Read this owner's
manual carefully and completely
before trying to assemble, op-
erate, or service this heater.
Improper use of this heater can
cause serious injury or death
from burns, fire, explosion,
electrical shock and carbon
monoxide poisoning.
Only a qualified installer, service
agent, or local gas supplier may
install and service this product.
WARNING: Keep flue open
when operating unit.
200247-01A
SPECIFICATIONS
45,000 BTU/Hr
FUEL INLET PRESSURE SPECIFICATIONS (W.C.)
Minimum 5.5" W.C. Maximum 10.5" W.C.
Minimum 11" W.C.
MINIMUM FIREBOX SIZES
Front
Model
Width*
FNVL18-1
24"
FNVL24-1
28"
FNVL30-1
34"
www.factorybuysdirect.com
Please make sure that all of the specifications
shown are applicable before installation is
attempted.
The fireplace must include a working flue and
venting system with the minimum openings
shown as below.
FNVL18-1
Natural
55,000 BTU/Hr
8" Diameter
8" Diameter
205 (mm)
Maximum 13" W.C.
Back
Depth
Width *
18"
15"
22"
15"
32"
16"
SAFETY
Carbon Monoxide Poisoning: Early signs
of carbon monoxide poisoning resemble the
flu, with headaches, dizziness or nausea. If
you have these signs, the heater may not
be working properly. Get fresh air at once!
Have heater serviced. Some people are
more affected by carbon monoxide than oth-
ers. These include pregnant women, people
with heart or lung disease or anemia, those
under the influence of alcohol and those at
high altitudes.
Natural Gas: Natural gas is odorless. An
odor-making agent is added to the gas. The
odor helps you detect a gas leak. However,
the odor added to the gas can fade. Gas may
be present even though no odor exists.
FNVL24-1
FNVL30-1
Natural
65,000 BTU/Hr
8" Diameter
225 (mm)
Height
18"
18"
19"
Natural
242 (mm)
3