Ex‐ Gr. 
Pipe size 
 
 
DN20 
(¾") 
DN25 
(1") 
DN32 
(1¼") 
DN40 
(1½") 
DN50 
(2") 
DN65 
(2½") 
IIA 
DN80 
(3") 
DN100  (4") 
DN125  (5") 
DN150  (6") 
DN200  (8") 
DN250  (10") 
DN300  (12") 
Chart 3: Types of explosion group IIA (MESG > 0,9 mm) protect against deflagration and short time burning 
maximum time of stabilized burning 1 minute 
 
The suitability for the application in gas/air mixtures and vapor/air mixtures of inflammable liquids of the 
explosion  group  IIA1  and  IIA  has  been  confirmed  by  the  successful  testing  at  IBExU  in  Freiberg  (stated 
location  No.  0637)  according  to  article  17  of  the  Directive  2014/34/EU  with  the  respective  EC‐/EU‐type 
examination certificate. Under atmospheric conditions (pressure: 80 to110 kPa(abs.), temperature: ‐20 to 
+60⁰C) the flame arrestors according to the charts 1‐3 are suitable for protection against deflagration. 
 
In case of a stabilized burning situation not limited by time and an operating pressure (p
the  flame  arrestors  according  to  chart  1  are  protected  against  endurance  burning.  Attention!  The 
protection  against  endurance  burning  refers  exclusively  to  the  existence  of  pure  hydrocarbons.  An 
application extended to other chemicals requires another testing with these specific chemicals. 
 
In case of a stabilized burning situation not limited by time and an operating pressure (p
the installation of at least one integrated temperature sensor on the unprotected side of the flame arrestor 
in  connection  with  activating  an  emergency  function  (e.g.  interrupting  or  inerting  an  gas  mixture)  with 
exceeding  the  operating  temperature  of  ≥  20K  is  obligatory.  The  maximum  acceptable  time  of  stabilized 
burning is 1 minute. 
 
The appropriate valid application  limits are documented at delivery referring  to the relevant EC‐/EU‐type 
examination certificate in the respective inspection certificate according to EN10204. The CE marking of the 
flame arrester documents the compliance with the safety and health requirements stated in the Directive 
2014/34/EU "
Equipment and protective systems intended for use in potentially explosive atmospheres
the respective declaration of compliance. 
 
The  flame  arrestors  shall  only  be  used  when  their  material  is  resistant  to  mechanical  and/or  chemical 
influences  or  corrosion  under  respective  operating  conditions  so  that  the  explosion  prevention  and 
protection are not set aside. This is especially applicable to the crimped metal ribbon of the flame arrestors 
whose safety against flame propagation may be put at risk by corrosion. 
 
 
04/16 
Type 
p
 
0
 
[kPa(abs.)] 
6A3Y6 
160 
6A3Z6 
160 
6A462 
120 
6A4E2 
120 
6A4F2 
120 
6A4P2 
120 
6A4Y2 
120 
6A562 
120 
6A5D2 
120 
6A5E2 
120 
6A5N2 
120 
6A5X2 
120 
6A642 
120 
 
T
 
L
 
EC‐type examination 
0
u
[°C] 
[m] 
certificate 
60 
1,00 
60 
1,25 
60 
1,60 
60 
2,00 
60 
2,50 
60 
3,25 
60 
4,00 
IBExU13ATEX2123 X 
60 
5,00 
60 
6,25 
60 
7,50 
60 
10,0 
60 
12,5 
60 
15,0 
 
) ≤110 kPa(abs.) 
0
) >110 kPa(abs.) 
0
" by 