USE AND MAINTENANCE MANUAL

3.5 SAFETY PROCEDURES DURING USE

TO USE the painting unit
STRICTLY OBSERVE
ASTURO ORIGINALI MAVES Spa declines every responsibility whatsoever in case the
user does not observe said precautions and safety criteria; furthermore, it is not responsible
for any kind of negligence when using the equipment.
I
Check the good functioning of the safety devices before working.The hand and the finger
protections must always be mounted on the gun when operating. Always insert the safety
lock placed on the trigger when interrupting the spraying, also for a short time, in order to
avoid an accidental functioning of the gun. TURN THE LOCK COUNTERCLOCKWISE
to insert the trigger safety lock and CLOCKWISE to disconnect it.
I
HAND PROTECTION 3. Before activating the gun, mount the hand protection correctly
between the sleeve and the gun body (on the upper side) and lock it to the rotating
adapter on the lower side. This safety device hinders the accidental functioning of the
gun in case it is hit or falls down.
I
FINGER PROTECTION 2. Always mount the finger protection on the gun in order to
avoid putting your fingers or other part of the body accidentally in front of the gun. The
finger protection must always be mounted with its packing. IF THE NOZZLE CLOGS
UP, INSERT THE TRIGGER SAFETY LOCK IMMEDIATELY. BEFORE REMOVING
MATERIAL RESIDUES AROUND THE NOZZLE, COMPLETELY DISCHARGE THE
PRESSURE IN THE SYSTEM.
I
An improper use of the equipment and its components can cause serious injuries.
Carefully read the technical features described in this manual and never exceed the
pressure values given. Do not use worn-out or defective components, but only ASTURO
ORIGINALI MAVES spare parts. Do not use the equipment other than originally designed.
Carefully check the components and replace those worn-out or defective. The high
working pressure can cause serious injections of toxic substances into the body.
IMPORTANT: Injections must be treated by qualified medical staff as soon as possible.
Inform the doctor of the paint and thinner types used.
I
HIGH pressure paint circulates in the hoses. Pay attention to breaks, cuts or slight leaks
which can cause injections into the skin or other serious injuries. Always use high pressure
hoses, check the connections before starting up the system, do not bend hoses near
fittings and do not use damaged or worn-out hoses, do not attempt to repair eventual
leaks. The paint flowing in the hose at a high speed causes static electricity: always
check that the system is grounded.
the following precautions and safety criteria.
WARNING
®