Danfoss 014G0013 Краткое руководство - Страница 3

Просмотреть онлайн или скачать pdf Краткое руководство для Термостат Danfoss 014G0013. Danfoss 014G0013 4 страницы. Electronic radiator thermostat

Danfoss 014G0013 Краткое руководство
Quick Guide
Technical requirements and info
• After a succesful inclusion the controller must send a WAKE_
UP_INTERVAL_SET command to living connect® Z in order to
specify where and when living connect® Z should communicate
wirelessly. If not, the thermostat cannot perform wake ups and
the alarm
and antenna symbols
• The nodeID set in the WAKE_UP_INTERVAL_SET command
must be for a permanently listening device which reponds to
the commands sent from living connect® Z. This means PC's with
USB sticks will only work if the PC is never turned off.
• If living connect® Z does not get correct and timely replies (e.g.
if the controller is turned of) it will automatically switch to 30 min-
utes wake up intervals. If at next wake up the controller replies
as expected, living connect® Z will switch back to the original
wake up interval.
• After sending the WAKE_UP_INTERVAL_SET command, the
controller must assign return routes, so living connect® Z can
reach its destination, i.e. the no-deID set in the WAKE_UP_IN-
TERVAL_SET command.
• living connect® Z will not commence its periodic communications
if it is in "Mounting mode". "Mounting mode" is for physical
installation and should not be confused with "Inclusion". Please
see section "Installing living connect® Z, item 4" for instructions
on how to leave "Mounting mode".
• Although living connect® Z supports single commands, multi
commands must always be used to ensure two years battery
lifetime.
• If multiple thermostats are installed in the same room, it is
important that the controller ensures they all have the same
schedule and the same setpoint.
Troubleshooting
Error code
E1, E2, E3, E4
Contact your local Service Technician.
The thermostat is not receiving the expected
replies from the control system.
Check that you have a Z-wave certified
E5
controller running and it has the necessary
functionality to control the thermostat (see
"Technical requirements").
living connect® Z, Electronic Radiator Thermostat
will flash.
Action
Safety precautions
The thermostat is not intended for children and must not be
used as a toy.
Do not leave packaging materials where children may be
tempted to play with them, as this is extremely dangerous.
Do not attempt to dismantle the thermostat as it contains no
user-serviceable parts. If error code E1, E2 etc. is shown in the
display or other defects appear, please return the thermostat
to the distributor.
VQIDC202
© Danfoss
Technical specifications
Thermostat type
Recommended use
Actuator
Display
Software classification
Control
Transmission frequency
Transmission range
Power supply
Power consumption
Battery life
Low battery signal
Ambient temperature
Transportation temperature -20 to 65°C
Max. water temperature
Temperature setting range
Measurement interval
Clock accuracy
Spindle movement
Noise level
Safety classification
Weight
IP class*
Tested for safety and EMC requirements as specified in EN 60730-1,
EN 60730-2-9 and EN 60730-2-14.
12/2014
Programmable electronic radia-
tor valve controller
Residential (pollution degree 2)
Electro-mechanical
Grey with back-light
A
PID
868.42 MHz
up to 30 m
2 x 1.5V AA alkaline, class III
3 µW in standby,
1.2 W when active
2 years
Battery icon will flash in display.
If battery level is critical, the
display will flash.
0 to 40°C
90°C
4 to 28°C
Measures temperature every
minute
+/- 10 min./year
Linear, up to 4.5 mm, max. 2 mm
on valve (1 mm/s)
<30 dBA
Type 1
177 g incl. RA adapter
20
3