Danfoss APPW 5.1 Руководство по эксплуатации - Страница 4
Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Водяной насос Danfoss APPW 5.1. Danfoss APPW 5.1 12 страниц. Disassembling and assembling
Service guide | Disassembling and Assembling, APP(W) 5.1-10.2
© Danfoss | DCS (im) | 2017.06
9. Remove the O-rings and back-up rings
from the valve plate.
10. Mount the new back-up rings on the new
valve plate.
12. Carefully press, by hand, the cylinder
barrel onto the valve plate.
8. Carefully remove the valve plate assembly
using a screwdriver.
Mount backup
ring first
Then mount
O-ring
11. Mount the new O-rings.
13. Remove the port plate by hand.
180R9238 | DKCFN.PI.078.F3.02 | 521B1196 | 4