Duomo BX308 XP Краткое руководство по эксплуатации - Страница 12

Просмотреть онлайн или скачать pdf Краткое руководство по эксплуатации для Контроллер Duomo BX308 XP. Duomo BX308 XP 17 страниц. 8 sensor gas detection controller

BX308 XP Gas Detection Controller

Compatible Sensors

Sensor
Sensor type
SG500
Catalytic
IP30
SG544
Catalytic
IP44
SGM595
Catalytic
IP55
SGM595/A
Catalytic
IP66
SGM533
Catalytic
IP55
SG800
Catalytic
IP66
SG870
Optical Flur.
IP64
SG880
Infrared
IP66
HCF100
Semiconductor
IP55
SG895
Catalytic
ATEX
SG580
Catalytic
IP66
SGF100
Catalytic
IP64
SGF102
Catalytic
IP64
SGF104
Optical Flur.
IP64
SGF106
Semiconductor
IP64
SGF108
Electrochemical
IP64
SGF110
Electrochemical
IP64
SGF112
Catalytic
IP64
CO100r
Electrochemical
IP55
CO100Ar
Electrochemical
IP66
SG800 Duct
Catalytic
IP66
SG800
Electrochemical
IP66

Sensor positioning

The BX308xp is a safety device designed to give audible
alarms and automatically provide latched electrical isolation
of associated gas safety shut off valves in the event of a gas
leak or build up of toxic gases.
The sensors can be located up to 100m from the gas detector.
Cable size should be 1mm
run separately in specific conduit it is not essential to use
screened cable but if the cables are routed through conduit
or trunking containing other wiring the use of screened cable
is advisable. The wiring should be performed by a qualified
person in accordance with current regulations. The plug-in
terminal rail makes installation easy and quick. Do not mount
close to any heat source or in an area where moisture is
likely to effect operation. The IP rating of this unit is IP44.
Sensors should be positioned as shown below.
If you require any guidance on this please call Duomo
technical support on +44 1905 797989.
t: 01905 797989
e: [email protected] | w: www.duomo.co.uk
IP Rating
Zone suitability
Target gas
Safe Area
CH4 / LPG
Safe Area
CH4 / LPG
Safe Area
See catalist
Zone 2 NE
See catalist
Safe Area
See catalist
Zone 2 NE
See catalist
Zone 2 NE
Oxygen
Zone 2 NE
CO2
Safe Area
Freon/Ammonia
Hazardous Area
See catalist
Zone 2 NE
See catalist
Zone 2 NE
CH4
Safe Area
CH4 / LPG
Safe Area
CH4 / LPG
Safe Area
CH4 / LPG
Safe Area
CH4 / LPG
Safe Area
CH4 / LPG
Safe Area
CH4 / LPG
Safe Area
CO
Zone 2 NE
CO
Zone 2 NE
CH4 / LPG
Zone 2 NE
CO
CSA. If the sensor cables are
2
Working range
Output
0-100% LEL
4-20mA
0-100% LEL
4-20mA
0-100% LEL
4-20mA
0-100% LEL
4-20mA
0-100% LEL
4-20mA
0-100% LEL
4-20mA
In %
4-20mA
0-100% LEL
4-20mA
0-300 ppm
4-20mA
0-100% LEL
4-20mA
0-100% LEL
4-20mA
0-100% LEL
4-20mA
0-100% LEL
4-20mA
0-100% LEL
4-20mA
0-300 ppm
4-20mA
0-300 ppm
4-20mA
0-300 ppm
4-20mA
0-100% LEL
4-20mA
0-300 ppm
4-20mA
0-300 ppm
4-20mA
0-100% LEL
4-20mA
0-300 ppm
4-20mA
12
Accuracy
Auto
Calibration
+/- 5%
No
No
+/- 5%
No
No
+/- 5%
Yes
No
+/- 5%
Yes
No
+/- 5%
Yes
Yes
+/- 5%
Yes
Yes
+/- 5%
Yes
Yes
+/- 5%
Yes
Yes
+/- 5%
No
Yes
+/- 5%
Yes
No
+/- 5%
No
No
+/- 5%
Yes
Yes
+/- 5%
Yes
Yes
+/- 5%
Yes
Yes
+/- 5%
Yes
Yes
+/- 5%
Yes
Yes
+/- 5%
Yes
Yes
+/- 5%
Yes
Yes
+/- 5%
Yes
Yes
+/- 5%
Yes
Yes
+/- 5%
Yes
Yes
+/- 5%
Yes
Yes
Relay