ADDRESS DESCRIPTION
Hereafter the description of charging station addresses:
SERIAL_NUMBER: 40000
The address contains the unique serial number of the charging station.
SW_VERSION: 40008
The address contains the revision of software or firmware of the charging station.
MDBUS_VERSION: 40012
The address contains the revision of the Modbus map.
HW_TYPE: 40016
tbd
DEVICE_TYPE: 40017
The address indicates the electrical connection of the charging station:
•
0 = AC 1-phase
•
1 = AC 3-phase
HW_CURRENT_LIMIT: 40018
The address contains the Current Limit measured in mA according to the specific position of the
Rotary Switch
ACTUAL_ERROR: 40100
The address contains the current error occurred on the charging station