Danfoss 4MFCE1-12CUP15L Руководство по установке - Страница 8

Просмотреть онлайн или скачать pdf Руководство по установке для Промышленное оборудование Danfoss 4MFCE1-12CUP15L. Danfoss 4MFCE1-12CUP15L 10 страниц. Multiplate coupling

Perform following steps for assembly of plug half (male) coupling in xed plate:
A. Insert plug body in respective hole in movable plate such that shoulder of the plug body is rested
against plate surface.
B. Install Jam Nut on plug half from opposite end of plate and screw nut in clock-wise direction.
C. Hold Jam nut in position by using standard tool and inserting it in slots provided on Nut.
D. Using standard wrench, hold hex on end connection of coupling and rotate in clockwise direction
to apply torque as per above chart.
8.3

REPLACEMENT PART NUMBERS

Refer below table for ordering correct parts for replacement. Other end connections are also available upon request for
plug and socket coupling assemblies.
M u l t i F F P a r t n u m b e r
P l u g c o u p l i n g
4MFC-10CUP15LS11
10FFPCUP12LS21
4MFCE1-12CUP15L
12FFPCUP15LS21
4MFC-12CUP15L
12FFPCUP15LS21
4MFC-1015L
10FFP15LS21
4MFCE1-1015L
10FFP15LS21
6MFC-1015L
10FFP15LS21
9.0

OPERATING

Figure 5. Operating multiplate coupling
As shown in figure 5, two plates of assembly play major role in operation of connection and disconnection. Fixed plate
with lever and cover, and movable plate. Movable plate has plug (male) half and xed plate has socket (socket) half.
1. First step is to open cover/dust cap and clean plate surface from any dust/foreign particles.
S o c ke t co u p l i n g
D u s t c a p s e a l
10FFS15LS21
4MFS21-10S11
12FFS15LS21
4MFS21-12
12FFS15LS21
4MFS21-12
10FFS15LS21
4MFS21-10
10FFS15LS21
4MFS21-10
10FFS15LS21
6MFS21-10
8