Danish Interpretation Systems EX 6010 Руководство пользователя - Страница 12

Просмотреть онлайн или скачать pdf Руководство пользователя для Источник питания Danish Interpretation Systems EX 6010. Danish Interpretation Systems EX 6010 19 страниц. Digital conference system; extension power supply with repeater for increasing the system capacity in dds 5900 and dcs 6000 systems

Danish Interpretation Systems

System design

There are no settings to be done on the EX 6010
Extension Unit.
However it is important to observe, that the unit is
only repeating one of the chains on the CU 6105 or CU
6110 Central Unit.
So when designing a system to incorporate EX 6010
Extension units, bare in mind, that as the EX 6010
Extension Unit is repeating only one of the two
outputs on CU 6105 or one of the four outputs on CU

'Repeated chain' connection

When connecting the EX 6010 Extension Units to the
Figure 0-A
Repeated Chain connection
CU 6105 or CU 6110, the first EX is connected to the
'Loop through' connector.
The next EX 6010 Extension units can be connected to
either the other 'Loop through' connector or to one of
12
6110, the max. number of languages configured on
the four outputs (1, 2, 3 and 4) is totally max. 16.
If more languages are required, Interpreter sets for
those languages have to be connected either to
another EX 6010 Extension Unit, which is connected
to another of the four chains on the CU 6110, or
directly to one other of the four chains on a CU 6110.
the 'Repeated out' connectors. If using the 'Repeated'
outputs two more EX 6010 Extension units (or RP
6004 Repeaters) can be connected extending the
maximum cable length in one chain up to 680 m. The
above schematic is showing the connection using the
''Repeated chains' connectors.
User Manual EX 6010 rev F.doc
User Manual