Specifications
Gain: 25 dB
Maximum Output: 20V rms
Bandpass: 2Hz to more than 100kHz
Hum and Noise: 100 dB below 2.5V output
Distortion at 1.0 V output: less than .15% THD or IMD
Phase: inverts phase of all inputs at main out
Ouput Impedance: 100 ohms
Mechanical
Dimensions: 15.375"D x 19"W x 4.375"H
Net Weight: 19 lbs.
Fuses
The ET7 has two power transformers (one for the tube circuitry,
one for the control circuits), each of which is protected by a fuse. In
addition there is one fuse on the ac mains. A failure of any of these
fuses is a symptom of a more serious problem, and a competent
service technician should be consulted. In no event should these
fuses be replaced with a value or type different than that originally
supplied. Two of the fuses, F1 and F2 are located on the main pc
board near the power transformers. The third fuse, F3, is in a tray
that is part of the IEC power line connector. The correct fuse
values are:
If configured for 100 or 120V:
F1
F2
F3
If configured for 220 or 240V:
F1
F2
F3
Conrad-Johnson ET7 Owner's Manual
5 x 20 mm 500 mAmp, fast blow
5 x 20 mm T400 mAmp, slow blow
5 x 20 mm T800 mAmp, slow blow
5 x 20 mm 200 mAmp, fast blow
5 x 20 mm T200 mAmp, slow blow
5 x 20 mm T400 mAmp, slow blow