This installation and service manual are valid to the pump type S-WP series.
The series are manufactured in size S-WP1, S-WP2, S-WP3, S-WP4 and S-WP5, and in 3 applications:
1. Wet-Pit.
2. Dry-Pit.
3. Portable.
The S-WP pumps are single stage, and non-self-priming pumps.
They are designed for pumping water, wastewater with pollutants, as well as low-viscosity types of sludge.
The pumps can also be used as drainage pumps where sand and gravel occur.
The impeller design allows each individual impeller to be trimmed to your exact performance requirements.
ATEX and FM edition can be offered. Fee will be added. (FM exceptions for some models)
WARNING
If the location has a hazardous media, then make sure the pump has been delivered with the right approval.
If there are local restrictions concerning fire risks, they must be obeyed at all time.
The pumps meet EU's machine directive, see declaration of conformity at the back of this manual.
DanPumps A/S guarantees that the pumps' airborne noise level does not exceed the noise level between 70
to 74 dB (at normal operation).
WARNING
If people can get physical contact with the pump or the fluid that is being pumped at e.g. open excavations,
building sites or the like, a fault circuit-breaker (HFI or HPFI) must be mounted in the electrical installation. If
the pump is used in oceans, lakes etc. there must be a minimum safety distance of 20 meters between the
pump and any persons in the water. The national country and local standards have at all time to be
observed.
If there are local restrictions concerning fire risks, they must be obeyed.