Addonics Technologies RT134SDEU3 Руководство пользователя - Страница 4

Просмотреть онлайн или скачать pdf Руководство пользователя для Хранение Addonics Technologies RT134SDEU3. Addonics Technologies RT134SDEU3 8 страниц. Raid tower xiii

Addonics Technologies RT134SDEU3 Руководство пользователя
Setting or Modifying the RAID Mode
NOTE: Setting or modifying the RAID mode destroys all data.
1.
Follow the procedure for resetting the RAID Mode.
2.
Power down the unit and set the dip switch to the desired RAID Mode.
3.
While holding the SET button with a ballpoint pen, turn the unit on. A
long beep will sound from the Port Multiplier. The SET button may be released
once the long beep stops.
If instead of a long beep the Port Multiplier sounds a series of short beeps, an
error has occurred during configuration of the array.
Windows users may install the JMicron HW RAID Manager application located
on the SATA Controller CD. In the CD, browse to Configuration Utilities →
JMB393. The JMicron HW RAID Manager can be used to create, modify, and
monitor the health status of the RAID drives, and provide status alerts. When
configuring the RAID mode using the RAID Manager application, it is strongly
recommended to leave the dip switch in the factory default setting.
Using identical drives for all settings other than JBOD or LARGE is strongly
recommended. Creating a LARGE array using drives that have different
properties will use all space on all members, and performance will match that
of the member in use during any particular I/O operation. Creating a RAID
using drives that are not all the same size will result in all members using only
as much space as the smallest member. Creating a RAID using drives that
have different performance will degrade the overall performance of the array.
BZS Switch (SW1:1):
The BZ switch is used to silence the audible alarm buzzer. The OFF position
permits the audible alarm, and the ON position silences the audible alarm.
The BZ switch has immediate effect.
EZ Switch (SW1:2):
The EZ (spare) switch inhibits spares when ON. When in the OFF position,
all individual drives (not defined as members of an array) are considered
spare. Should a RAID become degraded, when the EZ switch is in the OFF
position a spare drive will be used automatically to rebuild the RAID, if
present. EZ mode is determined when the unit is powered up. Changing the
switch will have no effect until the unit has been re-powered.
www.addonics.com
Technical Support (M-F 8:30am - 6:00pm PST)
Phone: 408-453-6212
Email: www.addonics.com/support/query/