Thermal Cut-Out Device
This Conception Wall Fire is fitted with a thermal safety cut-out system, built-in to prevent
it overheating. Should the Conception Wall Fire start to overheat, the thermal safety cut-out
system will automatically operate and the Conception Wall Fire will switch off. The Conception
Wall Fire will only resume normal operation when it has cooled sufficiently.
When the thermal safety cut-out activates, the Conception Wall Fire should be left to cool for
approximately 15 minutes before using again.
Before turning the Conception Wall Fire back on, check that there is nothing obstructing the
airflow or blocking the air intake.
Bulb Replacement
Always unplug the Conception Wall Fire from the mains power supply and leave it to cool
completely before attempting to replace a bulb.
Remove the pebbles from the trim.
Loosen the two screws holding the semi-opaque cover in position and then remove the cover.
Remove the defective bulb by pulling it out of the holder. Replace with a 28 W 230 V SES E14 bulb.
Reassemble the Conception Wall Fire by fixing the semi-opaque cover back on and then
replacing the pebbles.
Note: Due to the indeterminate life span and the ease of replacement, the bulbs are specifically
excluded from the guarantee provided with this product.
Caution: Take care not to touch the bulbs with bare hands.
Troubleshooting
Problem
The Conception Wall Fire is
not operating.
The fan is not running.
No heat or light is being
emitted from the Conception
Wall Fire.
No light is being emiited from
the Conception Wall Fire.
12
Cause
The thermal cut-out device
has operated.
There may be a problem
with the power supply to the
Conception Wall Fire.
The bulb has blown.
EH0089 Conception Wall Fire
Solution
Replace the fuse.
Leave the Conception Wall
Fire to cool for 15 minutes
then switch it back on.
Check the mains power
supply by plugging in a working
appliance. If the mains power
supply is functional and the
cord or plug of the Conception
Wall Fire is suspected to be
faulty, have it checked by a
qualified electrician.
Check the bulb by
replacement.