AUDIOropa PRO LOOP DCCplus Руководство по эксплуатации - Страница 3

Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Усилитель AUDIOropa PRO LOOP DCCplus. AUDIOropa PRO LOOP DCCplus 14 страниц. Loop amplifier

1.1.1 Description of the indicators, controls and connectors at the front panel
(1)
Power supply indicator: The green LED goes on if the induction loop amplifier is switched on.
(2)
VU indicator: It shows the master VU level. 0 dB (red LED), -6 and -12 dB (yellow LED)
(3)
Level indicator for induction loop power: It shows the electrical current throught the loop.
(4)
Fault indicator: Shows a failed supervised function of the loop amplifier.
(5)
ON/OFF Switch: The loop amplifier is switched on and off with this switch.
(6)
Regulator to set the corresponding input sensitivity: Sets the input sensitivity of input IN1 and input IN2.
(7)
Bass control: Controls the low tones of the audio signal.
(8)
Treble control: Controls the high tones of the audio signal.
(9)
Loop integrity indicator: The LED is on if the connected loop is not broken.
(10)
Limiter indicator: The LED is on if the limiter is active.
(11)
AGC indicator: The LED is on if the automatic gain control (AGC) is active.
(12)
Power control: With this control you set the maximum electrical current of the induction loop.
(13)
Earphone jack: You can connect headphones to the amplifier.
1.2.1 Description of the indicators, controls and connectors at the rear panel
(14)
Fan outlet: Please do not cover it so that any heat generated by the device can be dissipated.
(15)
Fault output: Gives the status of the loop amplifier to other equipment.
(16)
Supervision switch: Switchs the supervision of the priority input on and off.
(17)
Line out: Connection for a external recording unit.
(18)
Metal loss compensation: Sets the metal loss compensation.
(19)
Master/Slave connection sockets: Connect master and slave amplifiers to this amplifier.
(20)
Voltage selector: Changes the voltage on which the amplifier should work.
(21)
Power supply (110/230V / 50/60Hz): Connection for mains power supply.
(22)
Priority input: Connection for systems which can override the audio signal on the induction loop.
For example a alarm system or a PA-system.
(23)
10k/5k selection switch: You can select the frequency range of the audio signal on the amplifier.
(24)
AGC/LIMITER Switch: You can select the automatic gain control (AGC) or the limiter.
(25)
AGC control regulator: Regulats the range of the automatic gain control.
(26)
MIX/VOX Switch: Select if an audio signal of input 2 should override an audio signal of input 1 or if both
audio signals are mixed.
(27)
Audio inputs: Connection for external audio sources.
(28)
Screw terminal for the connection of the loop: The both ends of the loop cable will be connected here.
(29)
Screw for earth connection: Connects the loop amplifier to earth.
English 15