DanVex DEH-1200i Руководство - Страница 10

Просмотреть онлайн или скачать pdf Руководство для Осушитель DanVex DEH-1200i. DanVex DEH-1200i 14 страниц. Air dehumifiers
Также для DanVex DEH-1200i: Руководство по эксплуатации (20 страниц)

DanVex DEH-1200i Руководство
The timer is set using the TIMER, + / - buttons and is possible both to turn off the dehumidifier
from the working state, and to turn on the dehumidifier from the non-working state.
Settings are made in the corresponding modes:
TO DISABLE - in operating mode, press TIMER once, then +/- to set time in hours
(range 1–24 hours);
ON - in idle mode, press TIMER once, then +/- to set time in hours (range 1–24 hours).
Attention:
• The dehumidifier will not start if the humidity level set in the settings is higher than
current humidity;
• The dehumidifier will not start if the tank is full or missing;
• When operating in cold conditions, the compressor of the dryer may turn off to perform
a defrost, and the defrost indicator will light up on the display
• The display shows humidity in the range from 30% to 90%;
• If the dehumidifier is not to be used for a long time, unplug it.

5 MAINTENANCE

Before starting any maintenance work maintenance,
be sure to disconnect the dehumidifier from the mains!

5.1 Introduction

It is important to regularly inspect, maintain and clean the main components of the dryer to ensure
a long service life and trouble-free operation. The frequency of maintenance depends on the
operating conditions of the dryer. Thus, the maintenance cycle can be determined based on actual
operation. Incomplete and incorrect maintenance can reduce efficiency dryer or damage it.

5.2 Frame

Dust and other substances must not accumulate on the body of the dryer. It is recommended
to clean the case with a dry or slightly damp cloth without the use of solvents or abrasive detergents.
Use only non-aggressive cleaning agents, even if the unit is heavily soiled.
It is forbidden to clean the unit under the jet water!

5.3 Filter

The dehumidifier is equipped washable coarse air filter at the inlet. It protects the dryer heat
exchangers from fluff and household dust. Do not run the dryer without a filter.
It is recommended to clean the filter as it becomes clogged, but at least once every 2 weeks.

5.4 Heat exchanger

With the right operating the dryer with the air filter installed, the heat exchanger does not require
any maintenance.
www.danvex.fi
9
;