DanVex DEH-1600i Руководство по эксплуатации - Страница 12
Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Осушитель DanVex DEH-1600i. DanVex DEH-1600i 18 страниц.
Operating the machine
1. Energize the power, the dehumidifier will beep for once;
2. Press the "On/Off" button for once, the LCD display is light. After all the
displays are normal, the LCD displays current environment humidity;
3. Setting of humidity: press "+" and "-" buttons to set the required humidity.
When the set humidity is 3% less than current humidity, the dehumidifier works;
when the set humidity is 3% more than current humidity , the dehumidifier
stops.
4. When the set humidity is less than 30%, the dehumidifier enters the mode
of successive dehumidification.
5. Setting of preset time:
Press the "Time" button for the first time, the "hour" time on the display
flashes, press "+"and"-"to adjust the current hour and minute time; Press the
"Time" button for the second time,the "Start-up time" on the LCD flashes,
press "+"and"-"to adjust the current hour and minute time;Press the "Time"
button for the third time , the "Stop time" on the LCD flashes , Press
"+"and"-"to adjust the current hour and time;Press the "Time" button for the
forth time,the mode of "preset time "can be canceled.
6. After setting the mode of preset time, if the dehumidifier is shut off, it will
operate the whole mode of preset time; if it is in operation, it will operate the
mode of "preset stop time".
Operation Notices
1. When moving the machine, do not incline the machine for over 45°to avoid
damaging the compressor.
2. Temperature for operation of this machine is 5-35℃.
3. When it is operating,the compressor gives off heat when it works,and
ambient temperature may rise by 1-3℃.Such phenomenon is normal and is safe to use.
4. When ambient temperature is below 10℃ and absolute humidity is relatively
low,there is no need to use dehumidifier.
5. The air inlet and outlet must be away from the wall for at least 10cm in order
not to impair the dehumidification effect.
6. Working environment shall be as airproof as possible to maximize
dehumidification on effect.
7. Dust on the air purification filter mesh may impair its effect or even cause
failure. Please clear regularly for at least once a month. If there is much dust in the
environment,it must be cleared once a week or once a day. Pull down the front
panel,clear the filter mesh. Tap the filter mesh slightly or eliminate the dust by vacuum
cleaner or place the mesh in warm water(≤40℃ and add appropriate neutral
scour)and brush and then wash with clear water and dry it. Direct sunlight or baking
shall be avoided to prevent deformation.
We do not ensure the efficient operation
of the unit if the room temperature is
below 10 °C and if the relative humidity
is below 40 %.
11
R
www.danvex.fi