2.5.3 Dehumidification Section :
§
The system design has added an energy-saving heat exchanger, which adopts a combined design of a
liquid separator and a heat exchanger, which can effectively adjust the liquid flow function of the system,
and can also maximum the dehumidification capacity to ensure the optimal operation of the compressor.
The system adds a dry filter to effectively prevent the turbid impurities in the system from blocking the
expansion valve or capillary tube.
§
The defrosting adopts a patented structure device to ensure the stable operation of the refrigeration
system. The unique defrosting is gradually adopted without affecting the operation of the system.
§
The heat exchanger adopts hydrophilic membrane fins, the heat exchange efficiency is increased by 20%,
thus to reduce the unit size and weight. The high-quality thermal insulation material increases the
thermal insulation effect by 15%.
2.5.4 Compressor:
The compressor is the core part of the dehumidifier. Its performance characteristics directly affect the
performance and characteristics of the cabinet dehumidifier. The compressor is the core of the entire
dehumidification system and the source of system power. The power of the entire dehumidification is all
provided by the compressor. The compressor is equivalent to moving a physical object from a low potential
position to a high potential position. In the dehumidifier, its purpose is to compress the low-temperature gas
into high temperature through the compressor. Finally, the gas exchanges heat with other media in the heat
exchanger. The compressors are all imported brands.
2.5.5 Throttling Section:
The throttling component is one of the four indispensable components of the refrigeration system. Its
function is to throttle and reduce the pressure of the high-pressure liquid from the condenser, so that the
liquid refrigerant vaporizes and absorbs heat at low pressure (low temperature). Therefore, it is an important
part to maintain the high pressure in the condenser and the low pressure in the evaporator. Due to the direct
expansion method, the cooling loss is small and the efficiency is high. At the same time, it also has the
function of preventing liquid shock to protect the compressor and abnormal overheating. The expansion
valve has a stable degree of superheat, which makes the system run stably.
2.5.6 Controller Protection:
§
The self-developed dehumidifier controller has more powerful functions, and the overall operating
performance of the unit is higher, ensuring uninterrupted operation of the equipment.
§
Motor overload and short circuit protection: The supply fan motor and the compressor motor have
overload and short circuit protection functions.
§
Power-on protection: When the dehumidifier is turned off under normal circumstances, it will take 3
minutes to restart the protection when it is turned on again.
§
Shutdown protection: When the dehumidifier is turned off under normal circumstances, the fan will keep
working for 3 minutes to ensure the heat radiated.
§
Fan working mode: After the humidity is reached, you can choose whether the fan is running or not.
§
High-temperature protection: The unit is designed with high-temperature protection to prevent the
compressor from burning under continuous operation at high temperature.
§
Low-pressure protection: Prevent the compressor from burning out due to continuous operation without
refrigerant in the system.
5
2.5.7 Structure & Dimension
nameplate
fan
heat exchanger
compressor
condensate drain hole
cooling system
power cord
gas-liquid seperator
condensate
drain pipe
power
cord
electic box
filter
steel housing
600
1122
DEH-3K/5K
6