Duratool D03126 Руководство - Страница 6
Просмотреть онлайн или скачать pdf Руководство для Мультиметр Duratool D03126. Duratool D03126 8 страниц. Digital multimeter with backlight
AC VOLTAGE
Range
200V
600V
Overload protection: 600V DC or RMS. AC for all ranges.
Frequency range: 40Hz to 400Hz.
Response: average responding, calibrated in rms of a sine wave.
DIODE & CONTINUITY
Range
If continuity exists (about less than 1.5kΩ), the built-in buzzer will sound.
Shows the approximate forward voltage drop of the diode.
Overload protection: 250V DC or RMS, AC.
RESISTANCE
Range
200Ω
2kΩ
20kΩ
200kΩ
2MΩ
Maximum open circuit voltage: 3.2V
Overload protection: 250V DC or RMS, AC for all ranges.
TRANSISTOR hFE TEST (0-1000)
Range
NPN & PNP
OPERATION - DC VOLTAGE MEASUREMENT
•
Connect the red test lead to the "VΩmA" jack and the black lead to the "COM"
jack.
•
Set the rotary switch at the desired DCV position. If the voltage to be measured is
not known beforehand, set the range switch at the highest range position and then
reduce it until a satisfactory resolution is obtained.
•
Connect the test leads across the source or load being measured.
•
Read the voltage value on the LCD display along with the polarity of the red lead
connection.
Resolution
100mV
1V
Description
Resolution
0.1Ω
1Ω
10Ω
100Ω
1kΩ
Test Range
0-1000
6
Accuracy
± 1.2% of rdg ± 10 digits
± 1.2% of rdg ± 10 digits
± 0.8% of rdg ± 3 digits
± 0.8% of rdg ± 2 digits
± 0.8% of rdg ± 2 digits
± 0.8% of rdg ± 2 digits
± 1.0% of rdg ± 2 digits
Test Current
lb = 10µA
Accuracy
Test Voltage
Vce = 3V