Abus PLSG10000 Руководство пользователя - Страница 14

Просмотреть онлайн или скачать pdf Руководство пользователя для Датчики безопасности Abus PLSG10000. Abus PLSG10000 16 страниц. Z-wave indoor siren
Также для Abus PLSG10000: Краткое руководство (4 страниц)

3. Advanced Z-Wave Parameters

3.1. association groups

Z-Wave devices can control other devices directly. This direct control is called Z-Wave Association.
The device ID of the device to be controlled must be stored in the controlling devices. This is done in
so-called association groups. An association group is always linked to an event in the controlling device
(keystroke or triggering of a sensor). When this event occurs, a control command - usually a BASIC
SET - is sent to all devices stored in an association group.
The device supports one association group:
group
Maximum
number
appliances
Group 1
5
Group 1 (the Z-Wave Gateway)
When the device is supplied with power for the first time or the sabotage contact is triggered, the
device sends a notification report to the node of group 1.
If the battery level falls below a certain threshold, the device sends a battery report to the node of
group 1.
When a factory reset is performed, the device sends a Reset Locally Notification to the node of
group 1.
If the status of the siren changes (Piezo Alarm On/Off), the device sends a Switch Binary Report to
the node of group 1.
The device sends a multilevel sensor report with temperature and humidity values to the node of
group 1.
Notification report
The inside siren follows the Z-Wave Sound Switch Command Class for playback and control of the
audio files.
Event
Device is supplied with power for the
first time
Sabotage contact pressed for more than
three seconds
Sabotage contact pressed and released
for more than three seconds
Battery report
20-100
0xFF
profile
general
type
0x08
0x07
0x07
value
command class
notification report
battery report
Device Reset Locally Notification
Switch Binary Report
Sensor Multilevel Report
attribut
Event Parameter
e
0x01
0x01
0x00
0x03
Description of the
Battery Level %
low battery
14
English
Group Name
lifeline
Event
Length
Parameters
0x03