ATTENTION!
It is important these installation instructions
are followed.
We recommend our hearth products be in-
stalled and serviced by professionals who are
FHUWL¿HG LQ &DQDGD E\ :(77 :RRG (QHUJ\
Technology Transfer) or l'APC (l'association
GHV SURIHVVLRQQHOV GX FKDX DJH RU LQ WKH
U.S.A. by NFI (National Fireplace Institute).
WARNING
Failure to follow the installation instructions
could cause FIRE, CARBON MONOXIDE
POISONING, OR DEATH. If you are unsure
of installation requirements, call the Phone
Number listed on the instructions or visit
www.selkirkcorp.com.
TYPES OF APPLIANCES
Your Chimney Connector is intended to
connect a gas, liquid, or solid fuel appliance
QRUPDOO\ SURGXFLQJ ÀXH JDVHV RI &
) &DQDGD ) & 86$ RU
less to a factory built or masonry chimney. If
you are planning to install a wood stove, we
recommend that you:
- Use this chimney connector only with an
appliance listed by a recognized Testing Lab-
oratory (such as ULC, WH, ITS, UL or OMNI).
- Choose the right size stove. Do not buy one
larger than you need.
- Connect only one appliance to a chimney.
For mobile home installations follow the in-
stallation instructions for the mobile home
appliance and use the chimney connector
clearance required by the appliance.
PRE-INSTALLATION GUIDELINES
This Chimney Connector must not be en-
FORVHG RU SDVV WKURXJK DWWLFV FORVHWV ÀRRUV
or ceilings, and must not be used in place of
an insulated chimney section.
Plan the installation of your appliance and
chimney connector in such a way that your
chimney connector run is as short and straight
as possible.
By having too long and/or multiple bend in-
stallations you can reduce system draft which
FDQ D HFW WKH RSHUDWLRQ DQGRU SHUIRUPDQFH
of your appliance and/or chimney system.
4
7KH XVH RI WZR HOERZV LV RIWHQ SUHIHUDEOH
WR D VLQJOH HOERZ
Model USP warranty coverage will be nulled
DQG YRLG DQG VHULRXV ¿UH KHDOWK RU RWKHU
safety hazards may result from any of the
following actions:
- Installation of any damaged Chimney Connector;
8QDXWKRUL]HG PRGL¿FDWLRQV RI WKH &KLPQH\
Connector;
- Installation of any component part not man-
ufactured or approved with Model USP.
- Installation other than as instructed in the
installation instructions and the appliance
manufacturer's instructions.
Ensure you obtain any necessary building
permits, and your installation will conform
with all federal and municipal building code
requirements.
The Minimum Clearance to combustibles (i.e.
walls, ceilings, etc.) is 6" (152mm).
We recommend the maximum vertical run of
Double Wall Stove Pipe should not exceed 20ft.
CONTACT LOCAL BUILDING OR FIRE
OFFICIALS ABOUT RESTRICTIONS AND
INSTALLATION INSPECTIONS
Ensure the Wide Finishing Band covers any
single wall portion of the Pipe Adapter/Flue
Extension to provide 6" clearance.
3URYLGH VX FLHQW VORSH LQ WKH KRUL]RQWDO UXQ RI
the chimney connector (1/4" per foot, 20mm
per meter) to enable any condensed liquid or
creosote to run back toward the appliance.
When pipe is correctly placed and aligned,
all joints between sections of the chimney
connector must be secured with three sheet
metal screws per joints (#8 x 3/8" - supplied).
Some drilling may be required to the Stove
Pipe Adapter with a 3/32" metal drill bit.
If you are upgrading from a single wall stove
pipe to USP Double Wall Chimney Connector,
KDYH \RXU FKLPQH\ LQVSHFWHG E\ D FHUWL¿HG
ZRRG WHFKQLFLDQ RU D FHUWL¿HG FKLPQH\ VZHHS
Note: Diagrams & Illustrations Are Not to Scale.