9.

TECHNICAL PARAMETERS

9.1.

Electrical parameters

Power voltage
Power intake:
- with BAK fuel filler security
- without BAK fuel filler security
Analogue output signal for probe
Binary output signal for fuel filler security
RS-485 input/output signal:
-differential output voltage
-input voltage
RS-232LV input/output signal:
- TXD output signal
- RXD input signal
9.2.

Maximum ambient and working parameters

Working temperature range
Compensation temperature range
Relative humidity
Atmospheric pressure
Acceptable levels of vibration
Dusting
Working position
Concentration of active components in
atmosphere
9.3.

Measurement range data

Measurement range
Arm length in tank
Maximum range overload
9.4.

Processing errors

Fundamental error
Power voltage shift error
Hysteresis, repeatability
Additional ambient temp. shift error
Additional electromagnetic field effect error
(f=0,02...1GHz)
02.B.003
: Uzas = 8...32VDC
: < 75mA
: < 25mA
: U/CS = (0,05...10)V
:U/BAK = (0,002...0.9) Uzas
: min. 1,5V
: min. 0,2V
: HI > 3,0V; LO<0,2V
: HI > 2,0V; LO<0,8V
(-25...80) ºC (custom made -40 ºC ...80 ºC)
-25 ºC ...50 ºC
30...90%
80...120kPa
up to 2,5m/s
Vertical
No corrosive components
up to 2000mm H
Max 770mm (custom made up to 2000mm)
 100 kPa
 0,16%
0,05%
0,05%
0,3%/10 ºC
 1%
IO.CS-27/W.CS-27/BAK
2
Any
O
2
9