digit in the IP rating indicates protection against particle entry. A 5 indicates minimal dust entry with no
interference with fan operation. The second digit indicates water protection. A 5 indicates that water
sprayed on the fan from any direction shall have no harmful effects. Typical fans have particle and water
protection ratings of 2 to 3, indicating moderate particle and water protection, but no dust protection.
Dimensions: 22 cm height, 27 cm diameter
Mass: 840 g
Cables: 5 m of shielded, twisted-pair wire for fan and air temperature sensors
Additional cable available in multiples of 5 m
Santoprene rubber jacket (high water resistance, high UV stability, flexibility in cold conditions)
Pigtail lead wires
ST-110 (Precision Thermistor)
Measurement Range: -50 to 70 C
Measurement Uncertainty: 0.1 C (from 0 to 70 C)
Measurement Repeatability: < 0.01 C
Non-stability (Long-term Drift): < 0.02 C per year (when used in non-condensing environments where
the annual average temperature is less than 30 C; continuously high temperatures or continuously humid
environments increase drift rate)
Equilibration Time: 5 s
Self-Heating: < 0.01 C (typical, assuming pulsed excitation of 2.5 V DC)
0.08 C at 5 C (maximum, assuming continuous input excitation of 2.5 V DC)
Operating Environment: -50 to 70 C
Input Voltage Requirement: 2.5 V DC excitation (recommended, see OPERATION AND
MEASUREMENT section)
Output Voltage Range: 0 to 2.5 V DC (assuming input excitation of 2.5 V DC)
Current Drain: 0.1 mA DC at 70 C (maximum, assuming continuous input excitation of 2.5 V DC)
Dimensions: 7 cm length, 0.2 cm diameter
Mass: 60 g
0.15 C (from -35 to 0 C)
0 to 100 % relative humidity