AddSecure Edge RT7020 Enterprise Руководство пользователя - Страница 8
Просмотреть онлайн или скачать pdf Руководство пользователя для Система безопасности AddSecure Edge RT7020 Enterprise. AddSecure Edge RT7020 Enterprise 11 страниц.
7 The button "New hardware"
The button "New hardware" in Edge Manager is used for "releasing" a
configuration file. Meaning allowing for the configuration file to be used by
a new or a factory reset Edge RT7020.
7.1
Changing of PCB
Please note that if the PCB is exchanged on the unit a new activation of the
terminal towards the Connect platform, and the Alarm Receiving Centre,
must be performed. Therefore AddSecure and the ARC must be contacted.
•
•
•
•
•
7.2
Factory reset of the Edge RT7020 Enterprise
To reset an already installed Edge RT7020 to factory default:
•
•
•
•
•
•
•
•
•
Check that the replacement product is of the same type and model as the
product it's replacing. Make sure all connections and DIP-settings are done
in the same way on the new unit as on the old one. Finally power up the unit
and await the LEDs to indicate "Ready for programming".
Log onto Edge Manager and find the correct configuration file.
Click "New hardware"
Click "Program" and enter the Activation Code printed on the label of the
new unit.
Once the programming is completed, click "Commission".
Disconnect the power.
Put DIP3 in the ON position.
Connect the power.
Wait until the blue LED starts to blink.
IMPORTANT: Remember to reset the DIP3 to the OFF position (otherwise
the terminal will be factory reset again at the next power cycle)
Log on to Edge Manager and chose the correct configuration.
Click "New hardware"
Click "Program" and if needed enter the Activation Code.
Once the programming is completed, click "Commission".
8