SYSTEM FAULT
Indicates a system fault of the Controller-Expander, where:
-
A CPU or program execution is stopped or malfunctioning,
-
Storage memory containing config settings and audio files (SD card) is corrupted.
Where the system fault is caused by a CPU or memory fault, the device remains in its "safe state" where
critical functions (including audio transmission, reaction on control inputs, etc.) are stopped until the fault
is resolved.
OFF
YELLOW continuous
YELLOW blinking
NETWORK FAULT
Indicates when any device or link in the network is missing.
OFF
YELLOW continuous
YELLOW blinking slow
3. Rear panel
NOT USED
Page 5 of 10
Firmware and settings OK
CPU / program fault
o
o
o
Network OK
At least one device from the Local Network of this Controller-Expander is
missing.
Global ring is broken (any place in the ring)
Local network
ports
Global network
Device ID
ports
Author:
SD card fault
Config file not compatible
Wrong ID setting
Reset
button
microSD
USB
card
DD
24V DC input