Appion WS260 Руководство по эксплуатации - Страница 6
Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Весы Appion WS260. Appion WS260 12 страниц. Precision scale
Getting Started
1. Remove the WS260 from its protective case and place on a level and firm surface. If the scale is
used on a sloped or otherwise unstable surface, irregular or inaccurate readings may result.
2. Press the power button to turn on the WS260.
3. Take note of the reading on the display. If the reading does not show zero with an empty platform,
you should 'zero' the scale to ensure an accurate reading. Press and hold the TARE button to zero
the WS260.
4. With the scale properly zeroed, you may now weigh your materials.
5. If desired, connect to the Appion Central Mobile App to view remote readings, set alarms,
download data and more.
Bluetooth® Wireless Operation
NOTE: Bluetooth® communication requires a compatible device running the Appion Central Mobile App.
Visit the App Store or Google Play to download the latest version.
The WS260 is equipped with long range, low energy Bluetooth® technology. To connect to the
WS260, simply open the Appion Central Mobile App and navigate to the 'My Devices' submenu.
Bluetooth® connectivity is always enabled for ease of use and fast connections to your device. If
desired, you can change the range (Normal or Long Range) in the main menu of the WS260. Note
that changing to 'Long Range' will reduce battery life but enable up to ≈984ft (≈300m) line-of-sight
connectivity.
Menu Items
CLEAR ALARMS
Clear any alarms that have been triggered. Alarms are set using the Appion Central Mobile App.
MODE/RESOLUTION
Three resolution modes are available:
Normal: 10g / 0.5 oz / 0.1 lb resolution - Ideal for most applications
High: 1g (under 50kg)/ 10g (over 50kg) - Ideal for critical charge applications
0.1 oz / 0.01 lb (under 100lb), 0.5oz / 0.1 lb (over 100lb)
Extended Battery Life: 10g / 1 oz / 0.1 lb resolution - Up to 1200 hours battery life
CHANGE UNITS
The WS260 can display measurements in
DISPLAY SETTINGS
Change Backlight Timeout & Brightness, Rotate Display 180º, and toggle the Rate of Change view
on the main display.
DATA LOG
See Page 7 for more information
BLUETOOTH® RANGE
Two ranges are available; Normal (≈328ft/100m) & Long Range (≈984ft/300m) - [line-of-sight]
ZERO SCALE
Zeroing the scale will clear the reading and store the weight of an empty platform.
WS260 OPERATION MANUAL
© 2019 APPION INC. - ALL RIGHTS RESERVED
Kg
Kilograms
Pounds
Kg & g
6
Lb
Oz
Lb & Oz