AddSecure Edge VS5051 Руководство пользователя - Страница 10

Просмотреть онлайн или скачать pdf Руководство пользователя для Система внутренней связи AddSecure Edge VS5051. AddSecure Edge VS5051 14 страниц. Connect intercom
Также для AddSecure Edge VS5051: Руководство пользователя (10 страниц)

AddSecure Edge VS5051 Руководство пользователя

11 Maintenance routine

11.1 Periodic check of alarm

11.2 Maintaining data

11.3 Confirm current status

11.4 Periodic battery check

11.5 Perform full test and confirmation of alarms

page 10
If all the LEDs are correct, test the installation by initiating an alarm or a
voice call. This should be answered, which will indicate that there is a clear
two-way communication. Confirm with the support team that the elevator
alarm has been successfully delivered to the monitoring ARC.
Ensure that the monitoring ARC can initiate a call to the alarm or the voice
panel(s).
To complete the installation, please ensure that an end-to-end test is
performed with the ARC.
Maintenance routines are as follows:
 Periodic check of the alarm
 Maintaining data
 Confirm current status
 Periodic battery check
 Perform full test and confirmation of alarms
The alarm automatically makes a checking alarm call every 24 hours, so
other intermittent testing is not necessary. However, the alarm should be
tested by service engineers when service visits and elevator control testing
are done as required by EU directive 2014/33.
AddSecure keep the information about the location of the plant, phone
numbers and related information updated, based on input from the owner
or service partner. To change phone numbers and other account
information, please contact AddSecure Support.
You must ensure that information about building access, lift location,
contact persons and similar is kept up to date at the rescue services.
Check the status by checking the LEDs on the lid of the unit.
When a LED is lit, that indicates that this particular function is working
correctly.
The status of the battery should be manually checked periodically even
though the battery status is continuously tested automatically. If the self-
test finds the battery faulty, the Power LED will flicker. Also, a message will
be sent through AddSecure Connect to the ARC. The battery should then be
replaced with a new battery from AddSecure.
In conjunction with the ARC, you should now perform alarm and voice call
tests and, if necessary, other tests that the ARC needs to run or that are
PDK-13010-v.6.0 Edge VS5010 and VS5051 User manual