5.

Pneumatic connection

CAUTION
The following instructions must be observed if the pneumatic control is
to function properly.
The compressed-air ductwork system must be designed for a minimum
operating pressure of 5 bar to be maintained even at the moment of
peak air consumption.
The pneumatic system of the sewing unit must be supplied with
waterless compressed air.
The line pressure must be between 8 and 10 bar.
Connecting the compressed-air conditioner
Connect the hose 4 to the compressed-air ductwork system by
means of a type R 1/4" hose coupling.
Open the shut-off valve 3.
Adjusting the operating pressure
The operating pressure is 6 bar. It can be read off the pressure
gaugeÿ2.
Increase pressure =
Reduce pressure =
lift rotating handle 1 and turn clockwise.
lift rotating handle 1 and turn anti-clockwise.