Fitting the new parts

5.4 Installing thread lever protection

Abb. 20: Installing thread lever protection
1. Attach the thread lever protection (6) so that it is located as far down
2. Check the thread lever protection (6) does not collide with the thread
3. Tighten the screws (5) on the thread lever protection (6).
4. Loosen the screw (3) on the head cover (2).
5. Position the head cover (2) so it is flush with the machine again.
6. Insert the screw (1) on the head cover.
7. Tighten screws (1) and (3).
Abb. 21: Positioning the thread lever protection
Additional Instructions 550-867 - 01.0 - 08/2017
(1) - Screw
(2) - Head cover
(3) - Screw
from the sensor and as much to the right as possible from this and
thereby does not collide with the thread lever (4) .
lever (4).
(4) - Thread lever
(5) - Screws (concealed)
(6) - Thread lever protection