5.
Do not open the adhesive pack until you are ready to
apply the adhesive for installation – do not use the ad-
hesive if it has been opened for more than 5 minutes
6.
Only use supplied cleaning wipes for your installation
– do not sand or use any other cleaning agents on the
pod
7.
Only apply epoxy adhesive directly to the metal base of
the pod – do not put adhesive on your crank arm
8.
Do not attempt to clean off the excess epoxy with any
solvents – doing so may damage your power meter
9.
Only perform the pod installation in temperatures
above 20°C or 68°F – doing so will not allow the adhe-
sive to cure properly and will impact the accuracy of the
power meter
10. Do not expose the pod to temperatures above 50°C or
122°F
11. Do not install the pod on uneven or curved surfaces on
the crank arm
12. Do not install this power meter pod on carbon fiber
crank arms

1. Compatibility Check

1.1 Crank arm compatibility
Ensure that the crank arm has a flat surface for installing the
Precision
power meter pod.
TM
Figure 1.1
!
Visit
www.4iiii.com/precision
arm compatibility list and make sure your crank
arm is listed as being compatible with the
Precision
. The compatibility list is frequently
TM
updated.
4
to see the crank
1.2 Clearance Check
Make sure there is enough room between the crank arm
and the bicycle frame to install the Precision
pod. A minimum of 2 mm or 3/32 inch of space is present
between the Precision
pod and the bike frame
TM
>2 mm
>3/32 in
Figure 1.2
Do not remove the protective tape on the
!
metal plate at the bottom of the pod – doing
so may interfere with the accuracy and
reliability of the power meter.
To avoid contamination of the metal plate,
!
clean your crank arm with soap and water
prior to performing the clearance check. Once
the crank arm has been thoroughly cleaned,
dry the area with a lint-free cloth or shop rag.
power meter
TM
5