Datacolor AHIBA IR Pro Руководство по установке

Просмотреть онлайн или скачать pdf Руководство по установке для Промышленное оборудование Datacolor AHIBA IR Pro. Datacolor AHIBA IR Pro 3 страницы.

Doc. No. 72-990120-English
AHIBA IR & IR Pro
Quick Installation Guide
IMPORTANT: ALWAYS REFER TO USER MANUAL FOR MORE COMPLETE & DETAILED INSTRUCTIONS
1.
Ensure Installation site has the following:
Water (AHIBA IR Pro only):
Temperature:
Unit Foot Print:
2.
Open top of shipping box.
Remove system accessories box carefully.
Caution: Accessories box contains sensitive and fragile parts; handle with care to
prevent damage.
Check that the shipment is complete (Refer to included Packing Slip). The unit's controller and
mounting bracket are contained within a separate box. Remove the controller and mounting
bracket from this box and mount the controller on the unit using the screws mounted in the top
of the unit.
Be sure to connect controller grounding wire as shown in the diagram (Fig. 01).
Connect the I/O cable from the unit to the controller's rear panel. Ensure screws are tight.
Remove the unit from its pallet (caution: unit weighs approx. 74Kg (163 lb), a minimum of 2
people are required to lift).
Place unit of level and stable table/bench top with a minimum of 140 Kg load capacity.
3.
Provide sufficient space between the back of unit and the wall. The rear of the unit must be a minimum of 6 inches from any
surface. This is required for adequate airflow for the instrument fans and will prevent kinking of hoses if the unit is an AHIBA IR
Pro.
4.
During shipment the unit might be stored where ambient temperature is low. This could cause the thermostats to trip. Press
the Red Reset button located on the rear panel of the unit. (See fig. 02)
Ensure IR lamp circuit breaker is "on". (See fig. 02)
5.
6.
Refer to labels on the back of unit for proper connection.
(AHIBA IR Pro Only)
Caution: Improper installation of hoses can cause damage to the machine.
Important: The water outlet hose must always be channeled to a lower
elevation than machine water outlet.
Important!!! (AHIBA IR Pro only)
Before powering up the unit Slowly turn
inlet water on and check for any leaks.
Power:
230V ( 10%), 15A, 50/60 Hz, single phase with earth ground.
It is recommended to use surge protected and dedicated line.
Use only filtered and softened water.
Pressure:
2-3 bar (30-45 psi)
Hardness:
<10 dH
Ideally <15C
Min. diameter 3/8" (10mm), Hi Temp.
Hose:
864 x 597 x 648mm (H x W x D) minimum
(For detailed external dimensions and footprint – Refer to Technical Data section in User Manual)
Fig. 01
Fig. 02