Connecting a 1000BT-AT-SX to the the Network
FIGURE 2 — 1000BT-AT-SX Simple Connectivity Diagram
To connect the 1000BT-AT-SX into the network, refer to FIGURE 2 and
follow these steps:
IMPORTANT: The maximum length of 90 meters must not be exceed-
ed between end-points.
1. Before powering the TAP, connect one of the network device cables
to the 1000BT-AT-SX RJ45 port NETWORK A connector.
2. Before powering the TAP, connect the other network device cable to
the 1000BT-AT-SX RJ45 port NETWORK B connector. Ensure link
has been established between the NETWORK A device and NET-
WORK B device.
3. Connect the Power Supply barrel connector into the POWER port of
the 1000BT-AT-SX and then plug the Power Supply into the external
power source wall receptacle. The POWER LED to the right of the RJ
connectors illuminates indicating power is on.
The Rx-A, Tx-A, Rx-B, and Tx-B LEDs illuminate as data is passed
back and forth between the NETWORK A and NETWORK B device.
4. Connect one tap cable from the 1000BT-AT-SX RJ45 port TAP A
connector into one port of the Network Analysis Tool interface card.
The TAP-A LINK LED illuminates indicating link has been established
between the TAP A connector and Network Analysis Tool interface
card.
5. Connect the other tap cable from the 1000BT-AT-SX RJ45 port TAP
B connector into the other port of the Network Analysis Tool inter-
face card. The TAP-B LINK LED illuminates indicating link has been
established between the TAP B connector and Network Analysis Tool
interface card.
DATACOM
SYSTEMS INC
Access Your Network
CAUTION: Changes or modifications to this unit not expressly approved by the
party responsible for compliance could void the user's authority to operate the
equipment.
This equipment has been tested and found to meet the radiated and conducted
emission limits for a Class B product of EN 55022 to the EMC Directive
89/336/EEC requirements.
This equipment has been tested and found to meet the immunity levels for
Class 1 tested to level 2 for EN 6100-4-2, tested to level 3 for EN 61000-4-
3, tested to level 2 for EN 61000-4-4, and tested to level 3 for EN 61000-4-
5 to the EN 50082-1 requirements and meets the Class A requirements for EN
61000-3-2 and EN 61000-3-3.
This equipment has completed the Product Safety Review and found to meet the
Low Voltage Directive 72/23/EEC (1993) requirements.
Copyright
©
2004-2010 by Datacom Systems, Inc. All rights reserved.
Printed in the United States of America. No part of this publication may be
reproduced, stored in a retrieval system, or transmitted, in any form or by any
means, electronic, mechanical, photocopying, recording, or otherwise, with-
out the prior written permission of Datacom Systems, Inc. To obtain this per-
mission, write to the attention of the Datacom Systems legal department at
9 Adler Drive, East Syracuse, New York 13057-1290, or call 315-463-9541.
This Quick Installation Guide was written to help you get to know your new
10/100/1000BT-AT-SX quickly. We would welcome any comments or sugges-
tions you may have regarding this Quick Installation Guide. Please send your
remarks and recommendations via mail, telephone, facsimile, or Internet E-mail.
Datacom Customer Service personnel are available via telephone, facsimile, and
Internet E-mail. Please leave a voice message and our Customer Service Staff will
return your call as soon as possible.
Mail:
Datacom Systems, Inc.
Customer Service
9 Adler Drive
East Syracuse, NY 13057-1290
Tel:
(315) 463-9541
FAX:
(315) 463-9557
You can obtain additional information about
Datacom Systems, Inc. and its products and services from the World Wide Web
at http://www.datacomsystems.com or [email protected].
DATACOM
®
1000BT-AT-SX Full-Duplex Tap
Quick Installation Guide
May 2010
Part Number: 541-0078-A.01
Datacom Systems, Inc. (DSI) warrants that the hardware which it supplies will be free
from significant defects in materials and workmanship for a period of two years from
the date of delivery (Warranty Period), under normal use and conditions. In the event
of any such defect, you can return an item of defective hardware, freight prepaid, to
DSI during the Warranty Period, and DSI will repair or replace the defective equipment
and return it to you, freight prepaid. If DSI determines that the equipment is not defec-
tive, it will return it to you, freight collect. DSI shall have no responsibility for any
deficiency resulting from accidents, misuse, modifications, power disturbances
(including use of a power supply not specified by DSI), or various other forms of dis-
aster, e.g., earthquakes, floods, etc.
The warranties set forth above are exclusive and in lieu of all other warranties.
Datacom Systems, Inc. (DSI) makes no other warranties, expressed or implied, and
DSI expressly disclaims all other warranties, including but not limited to implied war-
ranties of merchantability and fitness for a particular purpose. Moreover, the provisions
set forth above state DSI's entire responsibility and your sole and exclusive remedy
with respect to any breach of warranty or contract.
No liability for consequential damages. Under no circumstances and under no theory
of Liability shall DSI be liable for costs of procurement of substitute products or serv-
ices, lost profits, lost savings, loss of information or data, or any other special, indirect,
consequential or incidental damages, arising in any way out of the sale of, use of, or
inability to use, any DSI product or service, even if DSI has been advised of the possi-
bility of such damages.