DATAGRABBER Rapid RH L6 Руководство по эксплуатации - Страница 13
Просмотреть онлайн или скачать pdf Руководство по эксплуатации для Регистраторы данных DATAGRABBER Rapid RH L6. DATAGRABBER Rapid RH L6 20 страниц.
Acclimation Time
The amount of time elapsed (in days) before the DataGrabber
will automatically capture (grab) a measurement and store
it in the L6 Smart Sensor's memory as the acclimated time
measurement of both RH and temperature. For instance,
setting an acclimation time of one day and then starting, the
DataGrabber will wait 24 hours and "grab" a measurement for
storage in the L6 Smart Sensor's memory. In most cases, it is
highly recommended to use one day as the acclimation time,
given that 24 hours is the minimum equilibration time specified
by the ASTM F2170 standard for getting official, documentable
RH readings.
NOTE
: Your DataGrabber device is "reusable" and not limited
to use with only one L6 sensor. To ensure that your device
properly utilizes the settings you configured, including the
acclimation time, be aware of the following when transferring
a DataGrabber device to another L6 sensor:
• For the DataGrabber, it takes up to one minute to turn
off after removal from an L6 sensor. If inserted into a
new sensor within that minute, the DataGrabber will
not detect the move until the next reading is taken.
• For the DataGrabber with Bluetooth, the process of
turning off the device after removal occurs much
quicker (about 5 seconds).
Log Interval
In addition to the reading captured (grabbed) when the
Acclimation Time has elapsed (see above), an L6 sensor, through
the DataGrabber with Bluetooth, will begin to capture readings
at a certain interval, defined as the Log (data logging) Interval.
This data logging of RH and temperature readings begins as
soon as the DataGrabber with Bluetooth is inserted into the
sensor, and a new set of readings is logged every time the Log
Interval is met. The default and minimum Log Interval is 1 hour.
Log Duration
A calculation of the total number of days that periodic time
and date-stamped readings will be taken based on the set log
interval and the L6 Smart Sensor's maximum memory storage
of 512 data points. Once this limit is reached, the first stored
reading will be overwritten.
WAGNER METERS
WWW.RAPIDRH.COM
11