Elsner P03/3 Технические характеристики и инструкции по установке - Страница 4
Просмотреть онлайн или скачать pdf Технические характеристики и инструкции по установке для Погодная станция Elsner P03/3. Elsner P03/3 11 страниц.
2.2. Installation position
Choose an installation position in the building where wind, rain and sun can be meas-
ured unhindered by the sensors. The weather station must not be installed underneath
any structural parts from which water can still drip onto the rain sensor after it has
stopped raining or snowing. The weather station must not be shaded by anything,
such as building structures or trees.
At least 60 cm of clearance must be left all round the weather station. This facilitates
correct wind speed measurement without eddies. The distance concurrently prevents
spray (raindrops hitting the device) or snow (snow penetration) from impairing the
measurement. It also does not allow birds to bite it.
Please take note that an extended awning does not shade the device from sun and
wind.
Temperature measurements can also be affected by external influences such as by
warming or cooling of the building structure on which the sensor is mounted, (sun-
light, heating or cold water pipes).
Wall
or
pole
P03/3 Weather Station • Status: 09.06.2016 • Technical changes reserved. Errors reserved.
4
Fig. 1
There must be at least 60 cm of space below,
to the sides and in front of the weather station
left from other elements (structures, con-
struction parts, etc.).
60 cm
Fig. 2
The weather station must be mounted on a
vertical wall (or a pole).
Installation and commissioning