DX6400 QUICK GUIDE
ELECTRICAL CONNECTIONS
The details of the connector pins are indicated in the following tables:
The table below gives the pinout of the CBX100/CBX500 terminal block connectors. Use this pinout when the
DX6400 reader is connected by means of the CBX100/CBX500:
Vdc
Power Supply Input Voltage +
GND
Power Supply Input Voltage -
Earth
Protection Earth Ground
+V
Power Source – Inputs
-V
Power Reference – Inputs
I1A
EXT TRIG/PS A (polarity insensitive) for PS
I1B
EXT TRIG/PS B (polarity insensitive) for PS
I2A
IN 2/ENC A (polarity insensitive) for Encoder
I2B
IN 2/ENC B (polarity insensitive) for Encoder
I3A
IN 3A (polarity insensitive) (
I4A
IN 4A (polarity insensitive) (
I34B
IN 3B/IN 4B Reference (polarity insensitive) (
+V
Power Source - Outputs
-V
Power Reference - Outputs
O1+
OUT 1+
O1-
OUT 1-
O2+
OUT 2+
O2-
OUT 2-
O3A
OUT 3A (polarity insensitive) (
O3B
OUT 3B (polarity insensitive) (
TX
Auxiliary Interface TX
RX
Auxiliary Interface RX
SGND
Auxiliary Interface Reference
Shield
Network Cable Shield
* Do not leave floating, see Reference Manual for connection details.
Do not connect GND and SGND to different (external) ground references. GND and SGND
are internally connected through filtering circuitry which can be permanently damaged if
subjected to voltage drops over 0.8 Vdc.
CAUTION
6
CBX100/500 Terminal Block Connectors
only with CBX500
only with CBX500
only with CBX500
only with CBX500
Auxiliary Interface
Main Interface
RS232
TX
RTS
RX
CTS
SGND
Power
Inputs
)
)
)
only with CBX500
Outputs
)
)
Shield
RS485 Full-Duplex
TX+
TX-
*RX+
*RX-
SGND
RS485 Half-Duplex
RTX+
RTX-
SGND